Background, Motivation and Objective It is very difficult to inspect thick sections of concrete and related material using ultrasound. The problem is mainly scattering from aggregate and other types of inclusions. This often limits the depth of penetration, but also causes a poor signal to noise ration (SNR) to be present in a single-sided inspection. The objective was to develop a system at low frequencies (100- 400 kHz), which had good penetration, but also had a reasonable bandwidth and SNR. This required the correct combination of transducer, excitation waveform and an additional signal processing method in term of defect location could be optimised.
其他文献
Background, Motivation and Objective In quantitative echocardiography, a robust and accurate automatic segmentation of the left ventricle (LV) is important. Poor image quality and the rapid motion of
会议
Background, Motivation and Objective Coded excitation can improve the signal-to-noise ratio (SNR) in medical ultrasound imaging.
会议
Background, Motivation and Objective Flow Mediated Dilation (FMD) is widely used to assess the endothelial function by ultrasound. Ideally, both the brachial artery wall shear stress (stimulus) and di
会议
Background, Motivation and Objective During neurosurgery, intraoperative imaging can serve to provide feedback on cerebrovascular hemodynamics and help monitor procedures such as the placement of flow
会议
Background, Motivation and Objective The peak blood velocity is a parameter of high medical interest used, for example, in the determination of carotid stenosis grade. The standard approach, which typ
会议
Background, Motivation and Objective Golay Complementary Sequence (GCS) can compensate the high attenuation of high-frequency ultrasound by elevating signal level with low range side lobe and low impl
会议
Background, Motivation and Objective In color flow imaging (CFI), achieving robust flow detection in the presence of tissue motion remains a long-standing challenge to be properly addressed. Key to ta
会议
Background, Motivation and Objective The twinkling artifact is a phenomenon that rapidly alternating color pixels behind a stationary strongly reflecting medium where an acoustic shadow is expected in
会议
Background, Motivation and Objective The well-known non-linear effect of acoustic radiation pressure, present in front of an emitting ultrasonic transducer, results in a net force that pushes the tran
会议
Background, Motivation and Objective High frequency hydrophone has been applied widely in the field of clinical applications. To determine the hydrophone sensitivity precisely has vital importance on
会议