Cognitive Function, Mood and Sleep Quality in Patients Treated with Intensity-Modulated Radiation Th

来源 :第九届泛珠江区域放射肿瘤学学术大会暨肿瘤放射治疗多中心协作研讨会、重庆市医学会放射肿瘤治疗学专业委员会2014年会 | 被引量 : 0次 | 上传用户:eg
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Objective: To prospectively evaluate the cognitive function, depression, anxiety, and sleep quality in patients with nasopharyngeal cancer (NPC) before and after intensity-modulated radiotherapy (IMRT).Methods: Eligible patients with newly diagnosed NPC treated with primary IMRT were recruited.A series of neuropsychological tests were performed within one week before and after IMRT.Cognitive function was measured with Das-Naglieri Cognitive Assessment System (D-N CAS).The Self-Rating Anxiety Scale (SAS) and Self-Rating Depression Scale (SDS) were used to assess mood states.Sleep quality was evaluated by means of the Pittsburgh Sleep Quality Index (PSQI).Results: A total of 51 patients were enrolled.The overall prevalence of depression, anxiety and poor sleep quality showed a significant increase after RT, compared with their pre-RT levels (39.2% vs.3.9%, P =0.000;19.6% vs.3.9%, P =0.039;64.7% vs.37.3%, P =0.003, respectively).Multiple linear regression analysis revealed that pre-RT depression and younger age, pre-RT anxiety and younger age were significant predictors of post-RT depression and anxiety, respectively (P < 0.05).Poor sleep quality before treatment was also associated with poor sleep after RT (P =0.032).However, the cognitive function evaluated by CAS from pre-RT was similar to the post-RT results.Conclusions: Exposure to ionizing radiation for the treatment of NPC decreased mood and sleep quality following IMRT, especially for patients with depression, anxiety, younger age or poor sleep before treatment.No acute cognitive deficits were found resulting from IMRT, but the long-term effects of RT might still warrant concern.
其他文献
  Objective: The optimal model of total dose and fraction size for locally recurrent nasopharyngeal carcinoma (NPC) with intensity-modulated radiotherapy (IMR
会议
  目的:应用Elekta Clarity超声图像引导系统(以下简称Clarity)与Elekta KV级锥形束CT图像引导系统(以下简称XVI)分析采用热塑性体膜固定下宫颈癌患者分次放射治疗宫颈移动
会议
  将基于经典demons算法与加速demons算法的弹性配准模型应用到放疗患者不同分次间的锥形束CT图像中,为进一步分析肿瘤及危机器官的变化提供软件支持.作者通过matlab软件编
会议
鸡西矿业集团公司张辰煤矿西三采区3
期刊
  目的 研究普通定位CT (3DCT)在不同扫描速度下获取的运动肿瘤靶区体积及中心位置的变化,并确定接近ITV的3DCT扫描速度.方法 利用QUASAR(Quality Assurance System for Ad
会议
  目的 考察不同的计划参数设置对两种TPS的鼻咽癌VMAT治疗计划质量与执行效率的影响,为临床计划优化设计提供参考依据.方法 随机选取25例鼻咽癌病例进行同步加量的VMAT计
会议
  目的:比较Elekta Synergy和Varian6EX二种MLC类型不同的直线加速器对鼻咽癌调强放疗计划的影响.方法:选择32例初诊的鼻咽癌患者纳入研究,首先使用头颈部热塑面罩固定,然后
会议
  目的:探讨脊髓3野与脊髓单野全中枢适形放疗计划的剂量学差异.方法: 以9例患者CT图像为基础,处方剂量30Gy,分别完成脊髓3野及脊髓单野全中枢适形计划,比较两种计划方式的剂
会议
鸡西矿业集团公司张辰煤矿西三采区3
期刊
  目的:探讨IGRT系统中患者BMI对摆位误差的影响.方法:对2013年2月-2014年1月我院70例胸和上腹部肿瘤(除乳腺癌)IGRT放疗的患者,按BMI特征分成两组.对每组中的每位患者在首次
会议