  Objective The aim of this paper is to study the methods of the 3D interactive clinging of MRI image in arbitrary orientation based on VTK.Materials or Methods The Visualization Toolkit (VTK) is an open-source,freely available software system for the development of 3D medical image visualization.In this paper,VTK was used to reconstruct the 3D images by using the MRI slice sequence in DICOM format based on MC (Marching cube) or RC (Raycasting) algorithms.A new method for 3D MRI image clipping based on VTK is presented,which can clip 3D object to observe the inner structure using 3D widget for manipulating an infinite plane.
其他文献
Objective: Establish a three-dimensional (3D) visualization system of medical images.Threedimensional visualization plays an essential and crucial role in disease diagnosis and treatment planning of p
To better explore the abundant information of brain regions involved in functional magnetic resonance imaging (fMRI) data during task status,especially the pattern of information transfer concerned in
Introduction Imaging is an essential tool to facilitate clinical diagnosis in ophthalmology.Currently most of the medical images are analyzed by human graders,which is very subjective.In this paper,co
会议
In this study,we developed a method of estimating the cerebral metabolic rate of glucose (CMRglc) using one sample of the input function in cerebral 18F-Fluoro-deoxigen-glucose (18F-FDG) positron emis
Focal spot size is an important factor that affects the spatial resolution and the projection image unsharpness.More seriously,the size and position of the focal spot may change as time goes or when t
目的 研究3D影像对观看者的影响,探讨脑电信号的功率谱特征与观看者不适感之间的联系,寻找用脑电信号的特征评价3D影像导致不适感的客观指标.方法 分别在3D和2D两种实验条件下,对实验前静息和实验过程中的脑电信号进行功率谱密度分析,采用统计分析方法进行假设检验并对照分析.
会议
[PURPOSE] To evaluate the accuracy (-)f the geometric calibration method for projection matrix computation and geometric parameter extraction,a cone-beam CT with a fiat-panel detector was simulated.MA
会议
Objective To present the methods of medical image quality assessment and optimization.Methods Based on human vision characteristics,the image vision quality parameters were analyzed in order to find t
呼吸运动引起较大幅度的胸腹部器官运动,造成传统CT图像上的运动伪影,影响放疗精确度及效率。四维CT(four-dimensional computed tomography,4DCT)技术能够提供反映内部器官运动的四维图像,有助于提高放疗精确度。传统4DCT技术在低剂量时将产生图像噪声及伪迹,且依赖于外部呼吸监测系统,无法在常规CT机上实现,使得设备昂贵。针对上述问题,本文提出基于图像最小边界不连