Real-time patient transit dose verification of volumetric modulated arc radiotherapy by a 2D ionizat

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:chenyinan
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose To explore the real-time dose verification method in volumetric modulated arc radiotherapy(VMAT)with a 2D array ion chamber array.Methods The 2D ion chamber array was fixed on the panel of electronic portal imaging device(EPID).Source-detector distance(SDD)was 140cm.8mm RW3 solid water was added to the 2D ion chamber array to improve the signal noise ratio.Patient plans for esophageal,prostate and liver cancers were selected to be delivered on the cylindrical Cheese phantom 5 times in order to validate the reproducibility of doses.Real-time patient transit dose measurements were performed at each fraction.Dose distributions were evaluated using gamma index criteria of 3mm DTA and 3%dose difference referred to the first time result.Results The gamma index pass rate in the Cheese phantom were about 98%; The gamma index pass rate for esophageal,prostate and liver cancer patient were about 92%,92%and 94%,respectively; Gamma pass rate for all single fraction were more than 90%.Conclusions The 2D array is capable of monitoring the real time transit doses during VMAT delivery.It is helpful to improve the treatment accuracy.
其他文献
Purpose:To investigate the accuracy of brachytherapy treatment planning system(TPS)dose distribution calculations for brachytherapy employing a shielded vaginal cylindrical applicator that reduces the
Purpose:The increasingly attractive stereotactic body radiation therapy(SBRT) for stage I lung cancer is accompanied by a large amount of monitor units(MU),leading to excessive out-of-field dose and p
会议
Purpose:Development of MR/CT compatible and tissue-equivalent phantom was proposed for MRI-only based radiotherapy.Materials and Methods:The MR/CT compatible and a new tissue-equivalent phantom was de
Purpose:To Time-of-Flight positron emission tomography(TOF-PET),the TOF benefit highly depends on the system timing precision.As a result,it is meaningful to measure the time resolution of the PET sys
Purpose:We study the dosimetric effect on the target volume,organs at risk(OARs)and normal tissues based on the different choice for four types of variables,namely,treatment position,dose calculation
Purpose:In this paper,we report the results of our investigation into whole brain radiotherapy(WBRT)using linear accelerator(Linac)-based intensity-modulated radiation therapy(IMRT)and volumetricmodul
Purpose:Abdominal compression is known to be effective but,often makes external-marker-based monitoring of breathing motion not feasible.In this study,we developed and evaluated a system that enables
会议
Purpose:To develop a patient-specific rectal toxicity predictor guided plan quality control tool for prostate SBRT plans.Methods:For prostate SBRT cases,rectal wall is identified as organs at risk and
The purpose of this study was to conduct quality assurance(QA)of plans of four patients having multiple metastatic lesions(targets)simultaneously treated with mono isocentric three dimensional conform
Purpose:This study aimed to determine the optimal fractions scheme(FS)in small peripheral non-small cell lung cancer(NSCLC)patients undergoing stereotactic body radiotherapy(SBRT)by comparing the ther