Decrease of Glomerular Filtration Rate may be Attributed to the Microcirculation Damage in Renal Art

来源 :第13届中国介入心脏病学大会(CJT2015) | 被引量 : 0次 | 上传用户:starfox_vip
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Background: The decrease of glomerular filtration rate has been theoretically supposed to be the result of low perfusion in renal artery stenosis (RAS).But the gap between artery stenosis and the glomerular filtration ability is still unclear.Methods: Patients with selective renal artery angiogram were divided by the degree of renal artery narrowing, level of estimated glomerular filtration rate (eGFR), respectively.The different levels of eGFR, renal microcirculation markers, and RAS severity were compared with each other, to determine the relationships among them.Results: A total of 215 consecutive patients were enrolled in the prospective cohort study.Concentrations of microcirculation markers had no significant difference between RAS group (RAS ≥ 50%) and no RAS group (RAS < 50%) or did not change correspondingly to RAS severity.The value of eGFR in RAS group was lower than that in the no RAS group, but it did not decline parallel to the progressive severity of RAS.The microcirculation markers presented integral difference if grouped by different eGFR level with negative tendency,especially that plasma cystatin C (cysC) and urinary microalbumin to creatinine ratio (mACR) increased with the deterioration of eGFR,with strong (r =-0.713, P < 0.001) and moderate (r =-0.580, P < 0.001) correlations.In the subgroup analysis of severe RAS (RAS ≥ 80%),the levels of plasma cysC and urinary mACR demonstrated stronger negative associations with eGFR, (r =-0.827, P < 0.001) and (r =-0.672, P < 0.001) correlations, respectively.Conclusions: Severity of RAS could not accurately predict the value of eGFR, whereas microcirculation impairment may substantially contribute to the glomerular filtration loss in patients with RAS.
其他文献
脑电图与脑电监测发明脑电图已经有几十年的历史.把脑电图用于临床麻醉监测,是近20年的事.将脑电波转变成其他形式叫做破译解码或分析,也叫脑电波的数学计算与分解.脑电波的
会议
1885年Dwyer在喉镜的辅助下应用气管内插管术治疗白喉,从而使气管内插管这种方法自古希腊时期后获得了新生.喉镜也从此登上了医学大舞台,在医疗事业中广泛使用.随着医疗技术
会议
一、概述概述三氯乙烯(TCE)作为种工业清洗剂,广泛用于电子、五金、电镀板清洗、粘合剂、去污剂等行业,主要用于产品的表面去污清洁、清洗、脱脂等用途,是目前我国最严重的职
会议
  Background: Studies have suggested that use of prolonged dual antiplatelet therapy (DAPT) following new generation drug-eluting stent implantation may incre
  Background: Lack of fluoroscopic landmarks can make valve deployment more difficult in patients with absent aortic valve (AV) calcification.The goal of this
Percutaneous coronary intervention (PCI) with implantation of drug-eluting stents (DESs) has become the standard of care for coronary artery disease and gives a
  Background: Recent studies reported that percutaneous coronary intervention with stent implantation was safe and feasible for the treatment of left main cor
  Background: We investigated whether and to what extent the ratio between circulating fibrinogen (Fg) and its degradation products (FDP)reflects the severity
  Background: Whether final kissing balloon (FKB) dilatation after one-stent implantation at left-main (LM) bifurcation site remains unclear.Therefore, this l
  Background: Coronary artery perforation (CAP) is a rare but severe complication of percutaneous coronary intervention (PCI).The aim of our study was to eval