  The output frequency of the atomic clock drifts slowly,called frequency drift,which is a majorfeature of the satellite rubidium (Rb) clock and determinesthe autonomic running duration of the satellite navigation system.Evaluation on Frequency drift of satellite rubidium clocks and analysis on factors contributing to frequency drift are carried out.Primary factors leading to frequency drift of rubidium clocks are pointed out and proposals aiming at reducing frequency drift are put forward.
其他文献
An algorithm of single-epoch integer ambiguity resolution for reference stations of BDS triple-frequency network RTK is proposed in this paper.And the mathematic models,resolution process and results
At present,the Galileo in-orbit satellites include four IOV(In-Orbit Validation)satellites and eight FOC(Full Operational Capability)satellites.The accuracy of Galileo positioning is better than 2 met
GNSS receiver usually use the match filter and FFT to get the code phase and carrier frequency.However,it is hard to get thecode phase and carrier frequency under high dynamic condition,And the match
GNSS compatibility and interoperability is one of the most significant problems in multi-system navigation and position.The precise prediction of system time offset is one of the most important proble
众所周知,当电缆在恶劣环境下运行时,容易造成绝缘性能的劣化,而电缆附件(包括中间接头和终端)是电缆线路的薄弱环节,其绝缘屏蔽口处的电应力集中容易发生故障。有研究表明,对于高压电缆线路运行故障,约80%以上都是由电缆附件引起的。因此局部放电试验能够有效检测并定位电缆附件中的潜在绝缘缺陷,是电缆状态评估工作的重要组成部分.本文从电缆附件的制作过程和安装工艺,分析了电缆附件发生局部放电的原因,其次详细介
Satellite-based Augmentation Systems (SBAS) can provide positioning services of 1m accuracy level by broadcasting real-time error correction products.However,the positioning accuracy of SBAS based on
本文以江苏地区为调查区域,针对水泥厂、化工厂、煤粉场、农业污染等几类典型污染源的现场挂网绝缘子进行采样分析,分别得到不同污源绝缘子的盐、灰密、离子成分以及颗粒物粒径分布数据,结果表明,化工厂污源和煤粉厂污源所含的无机盐含量最多,水泥污染源污秽中所含难溶物最多;根据实测数据规律,NO3-可表征化工类污源,NH4+可表征农田类污源.对几类典型污源自然污秽绝缘子,进行了高电导率雾对闪络电压影响的试验,结
电力设备的状态检测技术在电力系统中得到越来越广泛的应用,并取得了显著成效.本文首先对状态检测特别是带电检测技术的研究应用现状及面临的问题进行了总结,结合实际情况提出了输变配电设备状态检测实验平台的设计方案.然后,利用110kV GIS、变压器、电缆及10kV开关柜、箱变等真型设备,在机械结构、绝缘性能、内置传感器优化布局、典型缺陷设置等方面进行了设计改进,研制了变压器、GIS内置特高频局放传感器、
特高压直流穿墙套管是直流输电系统的关键设备,本文综合分析了多起特高压直流穿墙套管设计缺陷和工艺缺陷,剖析了对接式特高压直流穿墙套管的结构特点和在运行中存在的突出问题,并对如何提高对接式特高压直流穿墙套管的可靠性提出有效建议.
ZnO压敏电阻是金属氧化物避雷器(MOA)的核心器件.对ZnO压敏电阻老化劣化以及损坏模式的研究对MOA性能的改进具有重要意义.借助多脉冲平台,研究ZnO压敏电阻在动作负载以及不同多脉冲冲击源条件下的性能变化,结果显示:1)多脉冲作用下,金属氧化物均匀度不同会导致不同的破坏形式,贴片接触结构均匀度较差的金属氧化物主要发生贴片的融化剥落.热物理性能均匀度较差的则以压敏电阻体的热燃烧和粉碎性破裂为主.