脉冲管冷端和热端的层流化元件是脉冲管制冷机的重要部分。本文从流体力学、热力学出发,分析了小孔型脉冲管热端的流动过程和热力过程,确定了小孔型脉冲管的制冷机理。在此基础上,分析表明在脉冲管热端存在射流现象和涡流现象,导致一种气流混合的损失。本文称之为射流损失。设计了几种改进结构,实验验证了这种损失的存在同时也揭示了改进方法的有效性。 The pulse fluid tube cold end and hot end of the laminar flow element is a pulse tube refrigerator important part. Based on hydrodynamics and thermodynamics, this paper analyzes the flow and thermodynamic process of small-bore pulse tube hot end and determines the cooling mechanism of small-bore pulse tube. On this basis, the analysis shows that there is a jet phenomenon and a vortex phenomenon at the hot end of the pulse tube, resulting in a loss of mixed gas flow. This article is called jet loss. Several improved structures were designed. The existence of this loss was verified by experiments and the effectiveness of the improved method was also revealed.
其他文献
该文从机械系统电磁系统两个方面,针对底那米加速器电子束的散焦问题,进行修正,以确保电子束在扫描方向上的均匀性和一致性,提高辐照加工产品的质量。
时下,报刊上常出现一些语病,结果以讹传讹,颇呈流行之势。“孩提”的错用例:生活中的孙小梅多才多艺,孩提时代,孙小梅曾拉过11年的小提琴。例二:她孩提时代就喜欢体育运动,8
小孔、双向进气阀的开度是影响脉冲管制冷机性能的重要参数,该文根据高频微型制冷机最佳制冷性能的实验,对两种调节方式进行了比较,一种方式是传统的调节方式,即先调节小孔阀的最
单级基本型脉冲管制冷机的最低温度是124K.对于单级脉冲管制冷机制冷温度不能降低的原因,传统的看法为制冷量太小,或者说表面泵热的能力小。这里作者提出了一个新的观点,即基本型
半导体压力传感器的频率输出变换南通电极箔厂张台华在许多传感系统中,传感信号是其它模拟电路、控制逻辑电路或微控制器单元(MCU)的输入。为使传感器把它与压力有关的电压信号送给
该文对一典型的双向进气和多路旁通型脉冲管制冷机的动态压力、流速和温度的实验测量结果进行了详细的分析,得到了动态压力和质量流量之间的振幅度和相位关系以及脉冲管内部冷