Improvement and evaluation of deformation image registration on parotid glands during radiation ther

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:gyivan0513
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose:To quantitatively evaluate the strategic innovation and accuracy variation of deformation registration algorithm for parotid glands using the similarity Dice coefficient during the course of radiation therapy(RT)for nasopharyngeal cancer(NPC).Material and methods:Daily MVCT data for 10 patients with pathologically proven nasopharyngeal cancers were analyzed.The data were acquired using tomotherapy(TomoTherapy,Accuray)at the PLA General Hospital.The prescription dose to the primary target was 70Gy in 33 fractions.Two kinds of contours for parotid glands on daily MVCTs were obtained by populating these contours from planning CTs to the daily CTs via rigid-body registration with or without the rotation shifts using the in-house tools and the Adaptive plan software(Adaptive Plan,TomoTherapy),and were edited manually if necessary.The diffeomorphic Demons algorithm developed in the in-house tool was used to propagate the parotid structures from the daily CTs to planning CTs.The differences of the mapped parotid contours in two methods were evaluated using Dice similarity index(DSI).Two-tailed Pearson correlation analysis was carried out to compare the DSI changes during the course of RT.Results:For 10 patient plans,the accuracy of deformation image registration(DIR)with the rotation shift was obviously better than those without the rotation shift.The Dice scores of the left and right parotids for with and without the rotation shifts were found to be correlated with each other [0.90±0.04 vs 0.91±0.03(r=0.94,p<0.001); 0.91±0.03 vs 0.92±0.03(r=0.94,p<0.001)].The Dice scores for the parotids have shown the reduction with the changes of parotid volumes during RT.The DSI values between the first and last fraction were 0.93±0.02 vs 0.90±0.03 in 10 patient plans.Conclusion:DIR was successfully improved using the strategic innovation for ART.And the decrease of DIR accuracy has also been found during the delivery of fractionated radiotherapy.
其他文献
  1.Introduction: This research applies the Monte Carlo simulation method EGSnrc Electron Gamma Shower(EGSnrc)Code with two code is dedicated: BEAMnrc code is
会议
  Objective The paper is to perfect complete the QA process by developing of the method used to fast verify the center position of body patient which are trea
会议
  Purpose To evaluate feasibility and accuracy of various fiducial markers when using a gimbaled linac of Vero SBRT system for real time tumor tracking(RTTT).
会议
  Purpose:Between 1996-2000 a concept of Medical Physics started in Bangladesh offering 5-6 seminars/workshops in cooperation with Task Group 16 "Medical Phys
会议
  Objective:To study acute radiation-induced small bowel damage in patients with abdominal-and-pelvic tumor radiation therapy,in order to explore the clinical
会议
  Objective:To select reasonable treatment methods for liver tumor,the dose distribution by three-dimensional treatment planning system(TPS)for target area an
会议
会议
  Purpose:To quantitatively analyze the effect of TomoTherapy MVCT different scan options on IGRT(Image Guided Radiotherapy)and ART(Adaptive Radiotherapy)accu
会议
  Purpose:To improve an in-house fully automatic treatment planning system for radiotherapy of all kinds of cancer.Methods:The in-house autoplan system is a p
会议
会议