Purpose:Spectral computed tomography(CT) is known as a promising technique for obtaining enhancedimage with contrast agent.K-edge imaging is a useful method to distinguish different materials in spectralCT system.We focused on developing k-edge imaging for lower radiation exposure and shorter acquisitiontime by using sinogram interpolation.
其他文献
Purpose:In digital breast tomosynthesis(DBT) system,a series of projections with low exposure dose isacquired while the x-ray tube is rotated over a limited angle through the compressed breast.This ma
会议
Purpose:Phase-contrast X-ray CT imaging(PCT) is being used to observe various biological objects.The phase-contrast X-ray technique that detects X-ray phase-shift,has approximately 1000-times higher s
会议
Purpose Phase retrieval methods are used to disentangle pure phase from the phase contrast images.Thereare many phase retrieval methods available that address this issue.Two phase retrieval methods we
Background and purpose: The effect of methamphetamine(MA)abuser on human brain morphology has been reported.Several studies show evidence of structural brain abnormalities associated with abuse of MA.
Purpose:To estimate radiation dose received by the patient undergoing 64 slice MDCT examination using γ H2AX based technique.Methods:Somatom Definition AS CT Scanner machine,was used for this study.
会议
Purpose:Dual-modality systems offer great promise in improving detection and evaluation of cancerthrough improvement of the visual quality and quantitative accuracy.
会议
Purpose: This paper reports the relationship between Body Mass Index(BMI),tube voltages,tissue weighting factors,gender and the conversion factors of DLP,that can be used to estimate effective dose of
Pedicle screw(PS)implantation has been commonly applied in severe multilevel vertebra instabilities treatment.The accuracy of fixating PS is a key factor of spinal surgery.Investigating an ideal intra
Purpose Conventional golden ratio(CGR) based radial sampling scheme is efficient in dynamic MRI applications.[1]The sampling trajectory of shaking projection(SP) was provided to reduce the aliasing ar
Purpose Golden ratio based k-space trajectories [1] are widely used in dynamic MRI because it providesapproximate uniform k-space distribution.However,rapidlyswitching gradient induced eddy current,wh