新型眼生物测量仪Tomey OA-2000和IOLMaster获得的白内障患者眼生物参数的比较

来源 :眼科新进展 | 被引量 : 0次 | 上传用户:yuhuafenghao
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
目的 比较新型眼生物测量仪Tomey OA-2000与IOLMaster获得的白内障患者眼生物参数的差异性和一致性。方法 前瞻性研究。纳入白内障术前检查者74例(74眼),分别应用Tomey OA-2000和IOLMaster进行测量,获得眼轴长度(axial length,AL)、角膜曲率(keratometry,K)、前房深度(anterior chamber depth,ACD)和角膜横径(white to white,WTW)等参数。配对t检验分析两种设备获得的眼生物参数之间的差异。Bland-Altman散点图分析两种设备获得的各生物参数之间的一致性。结果 Tomey OA-2000获得的AL、平坦K(flat K,Kf)值、陡峭K(steep K,Ks)值、平均K(mean K,Km)值、中央角膜厚度(central corneal thickness,CCT)、ACD、晶状体厚度(lens thickness,LT)、瞳孔直径(pupil diameter,PD)和WTW值分别为(24.26±2.71)mm、(44.09±1.76)D、(45.01±1.73)D、(44.55±1.72)D、(518.41±34.18)μm、(3.07±0.48)mm、(4.48±0.61)mm、(4.07±0.95)mm和(11.50±0.52)mm。IOLMaster获得的AL、Kf、Ks、Km、ACD和WTW值分别为(24.33±2.69)mm、(44.21±1.74)mm、(45.15±1.76)D、(44.69±1.74)D、(3.04±0.46)mm和(11.65±0.41)mm。Tomey OA-2000和IOLMaster获得的AL、Kf、Ks、Km、ACD和WTW差值分别为(-0.07±0.10)mm(t=-5.99,P<0.01)、(-0.12±0.21)D(t=-4.14,P<0.01)、(-0.14±0.20)D(t=-5.88,P<0.01)、(-0.12±0.13)D(t=-7.44,P<0.01)、(0.03±0.14)mm(t=1.99,P=0.05)和(-0.14±0.32)mm(t=-3.73,P<0.01)。两种设备获得的AL、Kf、Ks、Km、ACD的95%一致性界限(LoA)其上下限最大绝对值分别为0.27 mm、0.50 D、0.53 D、0.38 D、0.30 mm,一致性较好;而WTW的95% LoA为0.78 mm,一致性较差。结论 Tomey OA-2000和IOLMaster获得的AL、K、ACD差异小,一致性好。 Objective To compare the differences and consistency of ocular biological parameters of cataract patients obtained with the new ophthalmic biometrics Tomey OA-2000 and IOLMaster. Methods Prospective study. Totally 74 patients (74 eyes) with preoperative cataract were included in this study. Tomey OA-2000 and IOLMaster were used respectively to measure axial length (AL), keratometry (K), anterior chamber depth , ACD), and white to white (WTW) parameters. Paired t-test analyzes the differences in ocular biological parameters obtained by both devices. The Bland-Altman scattergram analyzes the agreement between the biological parameters obtained by both devices. Results AL, flat K (Kf), steep K (Ks), mean K (Km), central corneal thickness (CCT) The values ​​of ACD, lens thickness (LT), pupil diameter (PD) and WTW were (24.26 ± 2.71) mm, (44.09 ± 1.76) D, (45.01 ± 1.73) D and (44.55 ± 1.72) D, (518.41 ± 34.18) μm, (3.07 ± 0.48) mm, (4.48 ± 0.61) mm, (4.07 ± 0.95) mm and (11.50 ± 0.52) mm respectively. The values ​​of AL, Kf, Ks, Km, ACD and WTW were (24.33 ± 2.69) mm, (44.21 ± 1.74) mm, (45.15 ± 1.76) D, (44.69 ± 1.74) D and (3.04 ± 0.46) mm and (11.65 ± 0.41) mm. The differences of AL, Kf, Ks, Km, ACD and WTW obtained by Tomey OA-2000 and IOLMaster were -0.07 ± 0.10 mm (t = -5.99, P <0.01) and (-0.12 ± 0.21) D = -4.14, P <0.01), (-0.14 ± 0.20) D (t = -5.88, P <0.01), (-0.12 ± 0.13) D (t = -7.44, P <0.01), (0.03 ± 0.14) mm (t = 1.99, P = 0.05) and (-0.14 ± 0.32) mm (t = -3.73, P & lt; 0.01). The 95% agreement limits (LoA) of the AL, Kf, Ks, Km and ACD obtained by the two devices are 0.27 mm, 0.50 D, 0.53 D, 0.38 D and 0.30 mm, respectively, ; While WTW’s 95% LoA was 0.78 mm, with less concordance. Conclusion The difference of AL, K and ACD between Tomey OA-2000 and IOLMaster is small and consistent.
其他文献
为研究复合土工膜对路面结构承载力的影响,采用贝克曼梁法,分晴天和雨天工况对普通路面结构以及加入两种不同复合土工膜的路面结构进行了弯沉值测定。试验结果表明:复合土工膜
依托长春地铁2号线袁家店站预制装配式地铁车站,利用MIDAS GTS NX软件建立单环地层-结构模型,考虑肥槽分级回填,分析回填不同材料时车站结构在位移、变形、内力等方面的变化
分析近年来我国新建高校筹资建设的实际情况,提出确立最优筹资方案,为学校多渠道筹措资金、化解风险、保证高校建设拓宽思路。
患者女性,53岁,主因“间断心悸5年,频发1年,加重1d”为主诉入院.患者5年前无明显诱因出现心悸、气短等不适,持续约几分钟至1小时不等.
运用粮畜生产协调度(CDGPAH)对福建省粮食生产和畜牧业发展协调状况的时空变化情况进行了定量分析。粮食生产和畜牧业发展协调状况的时序变化分析表明,1991—2005年来福建省粮食
毛茛属植物在系统分类上属于较为原始且又十分重要的一类植物,其研究对探讨被子植物的起源和进化具有一定的意义。本文从毛茛属的研究简史、形态学、细胞学和分子系统学这几
核心员工是企业的核心资源,其对整个企业未来的发展和企业战略目标的实现有着相当程度的影响。如何管理“好”企业的核心员工,发挥核心员工的比较优势服务于企业的战略发展已成
介绍了镇海炼化Ⅰ套气体分馏装置丙烷压缩机的机组参数,针对密封系统在实际运行中存在的密封油粘度下降和闪点不合格等情况,深入分析造成此情况的原因.通过对机组原浮环密封
随着城乡一体化进程的加快和国家扶持政策力度的加大,农村地区得到了较快的发展,村集体经济组织财务管理工作也呈现许多新的特点。介绍了农村集体经济组织财务管理存在的问题
本文从家庭教育的角度出发,以体育锻炼的隐性作用为切入点,采用问卷调查法、数理统计法、个案研究法等研究方法,对北京市海淀区部分少儿的家庭体育开展情况进行调查,对体育锻