Development of High Performance Autosampler for Front-end UHPLC to Improve LC/MS and LC/MS/MS Analys

来源 :第2届大连国际色谱学术报告会、第37届国际高效液相色谱及相关技术会议、第18届全国色谱学术报告会 | 被引量 : 0次 | 上传用户:areyoureadygolaopo
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  To speed up R&D in such areas as pharmacokinetics and synthesis in drug discovery, it has become increasingly necessary to analyze large numbers of samples at high speed and high precision.In response to these demands, the new Nexera MP Ultra High Performance Liquid Chromatograph (UHPLC) including the SIL-30ACMP Multi-plate Autosampler was developed.The SIL-30ACMP achieves an ultrafast injection performance exceeding that of current models while maintaining ultralow carryover performance.In addition, up to 6 microtiter plates can be loaded, enabling a maximum of 2304 samples to be analyzed continuously.We will present the new autosamplers technology including carryover reduction, improved reproducibility and ultra fast inj ection and so on.
其他文献
Several types of capillary array electrophoresis with laser-induced fluorescence detector (LIF-D) have been proposed since the development of high-speed DNA analysis.They included systems with four-co
The columns of Five-zone simulated moving bed (SMB) were divided into five zones by two inlets and three outlets as shows in Fig.1.Each column are equipped with the inlet and outlet, and by changing t
Ambient ionization mass spectrometry can usually meet the requirements for rapid and direct screening of analytes in urine, saliva, plasma, skin and hair.l-3 However, some practical problems still exi
Protein samples present a difficult problem in analytical chromatography.Very small differences in chemical structure can have a large impact on biological activity, and a single protein can harbor on
Successful and reliable chromatographic assays depend upon transferring the specified volume of a representative aliquot of sample to the column.The factors affecting the reliability and fidelity of t
Fluorescence detection has been one of the most sensitive and selective detection schemes available for capillary flow systems.Light Emitting Diode (LED) has the advantages including long lifetime, hi
Glucocorticoids (GCs) are the most effective anti-inflammatory drugs which are usually used for treatments of many inflammatory and immune diseases.1,2 The application of GCs in dermatology has brough
Size-exclusion chromatography is routinely used in many laboratories to separate macromolecules in solution according to their size.These molecules range from synthetic polymers such as polystyrene, t
Content and inpurity of trimesic acid (TMA) were determinated with high-performance liquid chromatography (HPLC).A qualitative and quantitative method for determinating TMA with HPLC was established.C
For the analysis of organic acids by HPLC, UV detection at around 210 nm has been conventionally used as a convenient and simple technique.The UV detection method, however, has poor sensitivity and/or