【摘 要】
:
Background,Motivation and Objective Parallel beamforming in transmit(PBT) by means of orthogonal frequency division multiplexing(OFDM) has recently been investigated as a means to improve the frame ra
【机 构】
:
Biomedical Diagnostics Lab.,Eindhoven University of Technology,Eindhoven,Netherlands
论文部分内容阅读
Background,Motivation and Objective Parallel beamforming in transmit(PBT) by means of orthogonal frequency division multiplexing(OFDM) has recently been investigated as a means to improve the frame rate of ultrasound tissue harmonic imaging.
其他文献
Background,Motivation and Objective We investigated the feasibility of a monitoring imaging method to visualize and evaluate the high intensity focused ultrasound(HIFU) induced lesion in vitro during
Background,Motivation and Objective Prostate cancer(PCa) is the most occurring type of cancer in the Western World.However,the most common diagnostic tool,systematic biopsy,is invasive and has low sen
Background,Motivation and Objective Functional transcranial Doppler ultrasound(fTCD) is a non-invasive sensing modality that measures blood flow velocities in cerebral arteries(CBFV) with high tempora
Background,Motivation and Objective In ophthalmic ultrasonography the crystalline lens is known to be the main source of phase aberration,as ultrasounds(US) propagate about 10 %faster than in the sur
Background,Motivation and Objective Traditional spatial compounding in general,employs multiple distinct transmit/receive beam angles which insonify a common region,from which multiple images are form
Background,Motivation and Objective For Doppler examination,intra-corporeal major vascular flows are relatively easy object for duplex or CFM scanner,shallow small flows are also easy for single beam
Background,Motivation and Objective In a row-column(RC) addressed 2-D array,the elements are accessed by their row index in transmit and by their column index in receive,or vice versa.This effectively
Background,Motivation and Objective High quality ultrasound imaging is required throughout entire imaging depths for abdominal ultrasound.In general,sector scanning with a convex array transducer is p
Background,Motivation and Objective In medical ultrasound imaging,a constant sound speed(e.g.,1540 m/s) is typically used for receive beamforming.However,due to inhomogeneity in soft tissues,the propa
Background,Motivation and Objective The synthetic aperture imaging(SAI) method in medical ultrasonic imaging is widely known for improving image quality by synthesizing the transmit focusing at all de