Comparativ analysis of the stenting treatment for symptomatic intracranial arterial stenosis with ba

来源 :首届中国神经介入大会 | 被引量 : 0次 | 上传用户:kyl1n
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Objective: By retrospectively analyzing the stenting treatment for 88 patients with symptomatic intracranial arterrial stennosis, to compare the predominance and shortage of both balloon-expandable stent vs the Wingspan stent system.Material and Methods: Eighty-eight patients (mean age 66.42 years; 33 male and 15 female patients) with symptomatic intracranial atheromatous stenosis (≥ 70%) were treated with the stent placement.All lesions treated involved the internal carotid artery (n=16), middle cerebral artery (n=28), V4 segment vertebral artery(n=25), basilar artery (n=19).Result: All 63 lesions with Gateway balloon-Wingspan system involved the internal carotid artery (n=12), middle cerebral artery (n=22), V4 segment vertebral artery(n=15), basilar artery (n=14).Sixty-two lesions were successfully treated with the deployment of the Wingspan stent.One case failed because of intracranial hemorrhage during the operation.The successful rate of stenting is 98.0%(62/63).And mean pretreatment stenosis was 82.3 ± 9.2%, improving to 23 ± 11.2% after stent placement.During the perioperation period of one month, 1 patient died of postprocedural hyper-perfusion, one with ischemic stroke during the operating day, one with Homer syndrome attack at the 11th day.The hemorrhage complication rate is 3.2% (2/63) , the ischemic complication rate is 3.2% (2/63) , and the severe stroke or mortality is 1.6% (1/63).All 25 lesions with balloon-expandable stent involved the internal carotid artery (n=4), middle cerebral artery (n=6), V4 segment vertebral artery(n=10), basilar artery (n=5).Three cases witn lesions in the anterocirculation failed because of unsuccessful targenting of stent.The successful rate of stenting is 88.0% (22/25).And mean pretreatment stenosis was 82%, improving to 14% after stent placement.During the perioperation period of one month, 2 cases with hemorrhage complication and the rate is 8% (2/25).One died of subdural hemorrhage and the other recovered.one with ischemic stroke during the operating day and the the ischemic complication rate is 4% (1/25) , and the severe stroke or mortality is 4% (1/25).Conclusion: the nitinol stent is more flexible than balloon-mounted stents.The technical success rate is higher and the complication rate is lower.But there is higher remnant stenosis because of insufficent radial force and the improvement is essensial.
其他文献
  Objective To evaluate the technical feasibility, safety and treatment effeciency of the acute and chronic occluded vertebrovacular artery endovacular recana
会议
  本文以贵州省岩头河大桥为工程背景,采用大型有限元软件研究了不对称连续刚构桥的动力特性。根据引起连续刚构桥不对称的原因分别研究了主梁不对称和桥墩不对称对结构动力
  本文以近年来大量建造的整体钢桥面板桁组合结构为研究对象,针对初步设计采用精细化方法耗时长、计算工作量巨大的缺点,提出了简化的空间杆系结构法(SF法)和主桁平面分解
  基于梁桥振动理论和达朗贝尔原理,桥梁采用等截面的贝努利-欧拉梁模型,车辆简化为一系悬挂的质量-弹簧列模型,采用Newmark-β法对高速列车荷载作用下简支梁桥的竖向共振响应
会议
  Objective To assess the safety, feasibility, short-and mid-term efficacy of wingspan stent for treating patients with symptomatic intracranial artery stenos
会议
康艺(Contec)8080-2S型收录两用机是一种中档双通道收录机.该机的收音和录放音性能符合一般使用要求,功能亦比较齐全,所以适合普通家庭作文艺欣赏和学习工具,是一种大家比较
  Intermediate Catheters in the posterior circulation-when is it most useful? Introduction: Stable access to target lesions is foundational to endovascular th
会议
  大跨度斜拉桥属于高次超静定结构,其求解索初拉力的过程通常需要具有相当经验的调索计算人员进行反复的迭代试算。本文给出一种基于影响矩阵和粒子群智能优化算法的调索计
(1)目的——研究、研制、调查等的前提、目的和任务,所涉及的主题范围。(2)方法——所用的原理、理论、条件、对象、材料、工艺、结构、手段、装备、程序等。(3)结果——实验