Improvement of an in-house fully automatic treatment planning system for radiotherapy of all kinds o

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:qwfyhwl
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose:To improve an in-house fully automatic treatment planning system for radiotherapy of all kinds of cancer.Methods:The in-house autoplan system is a patent expert system designed to be embedded in a treatment planning system that has integrated experts clinical and physics experience,and novel algorithms.For every new patient,the autoplan system could fully automatically generate plans that meet or exceed the institutions dose-volume constraints by one button click in the TPS.Previously,several kinds of cases including lung cancer,esophagus cancer,prostate cancer,base of tongue cancer can be applied to the autoplan system.More than 100 clinical plans of different kinds of cases including nasopharynx cancer,oralpharynx cancer,hypopharynx cancer,larynx cancer,tonsil cancer,parotid cancer,head and neck NK/T cell lymphoma,sinonasal carcinoma,lymphoma,thymoma,mesothelioma,breast cancer,cervical cancer,endometrial cancer,rectum cancer,bladder cancer,sarcoma,malignant melanoma,and different kinds of cancer with bone metastasis from 6 institutions were redesigned manually to summarize general optimization methods for every kinds of case.The general optimization method can nearly achieve the best OAR and normal tissue protection without too much target coverage compromise.The general optimization methods were then integrated in the autoplan system.Autoplans of these cases designed by the autoplan system were compared with these clinical plans by medical physicists and physicians.Results:IMRT and VMAT Plans of these kinds of cases can be generated automatically within 0.5 to 3 hours(1h on average)by one button click in the TPS.Every autoplans meet or exceed the institutions dose-volume constraints.Dose of all the OARs and normal tissue of autoplans is significant lower or not higher than that of clinical plans with similar target dose coverage.All the autoplans were preferred.CONCLUSIONS:The in-house fully automatic treatment planning system was improved for radiotherapy of all kinds of cancer.Plan quality was significant improved and human resources were greatly saved.
其他文献
Objective To evaluate CBCT image quality and its long-term stability for HUs in different scanning conditions.Materials and Methods With the OBI of Varian iX system,Catphan 504 phantom in the differen
To estimate the α/β ratio of late rectal toxicity in case of prostate cancer radiotherapy; and to investigate whether correcting the rectal dose-volume histogram(DVH)for differences in dose per fracti
Objective To compare the dosimetric difference between anisotropic analytical algorithm(AAA)and pencil beam convolution(PBC)for intensity modulated radiation therapy(IMRT)Plans in esophageal carcioma.
Purpose:The efficacy of spatially fractionated(GRID)radiotherapy for treating bulky tumors has been recognized and demonstrated.GRID therapy might improve tumor control while reducing normal tissue to
Purpose:Cone-beam x-ray luminescence computed tomography(CB-XLCT)opens new possibilities to perform molecular imaging with x-ray.The spatial resolution of CB-XLCT was limited because of severe ill-pos
Purpose:The purpose of this study was to test feasibility of clinical usage of flattening filter free(FFF)beam for treatment of lung stereotactic ablative radiotherapy(SABR).Methods:Ten patients were
Purpose:End-of-exhale(EOE) phase is generally preferred for gating window because tumor position is more reproducible.However,other gating windows might be more appropriate for dose distribution persp
会议
Purpose:To investigate the cumulative dose delivered to the High-risk clinical target volume(HR-CTV)throughout the course of cervix cancer treatment with external beam radiotherapy(EBRT)and brachyther
Purpose:PET visualization method is routinely used in clinical practice,however,it has high interobserver variations and relies on the experience of nuclear medicine physician.PET automated threshold
Purpose:To quantitatively evaluate the strategic innovation and accuracy variation of deformation registration algorithm for parotid glands using the similarity Dice coefficient during the course of r