在超高真空中温度测试上限要达到2600~3000℃。依据对测量数据进行多项式校正的理论和最小二乘数据拟合方法,给出了对钨铼5-钨铼26热电偶分度表进行全温度范围分段多项式校正的数学模型,阐述了提高校正数据精度的有效方法。实验证明,多段校正方法在-200~2310℃范围内精度可达±1‰。
In ultra-high vacuum temperature test ceiling to reach 2600 ~ 3000 ℃. Based on the theory of polynomial correction and the method of least square data fitting, the mathematical model of the polynomial correction of the temperature range of tungsten-rhenium-tungsten-rhenium-26 thermocouple indexing table is given. Effective method of data accuracy. Experiments show that the multi-step correction method in the range of -200 ~ 2310 ℃ accuracy of ± 1 ‰.