论文部分内容阅读
国内许多运行的 1 0 2 5t/h控制循环锅炉主要性能参数均能达到设计要求 ,低负荷稳燃性能好 ,启停速度快 ,调峰能力强。但是锅炉普遍存在再热器喷水量偏大的问题 ,影响了机组运行经济性。通过某台 1 0 2 5t/h控制循环锅炉再热器喷水的试验 ,分析研究影响再热器喷水量的因素 ,为同类型机组的设计优化、运行和改造提供参考。
Many domestic operation of the 1022t / h control cycle boiler main performance parameters can meet the design requirements, low load stable performance, start and stop fast, peak shaving ability. However, the boiler generally has the problem that the reheater water quantity is too large, which affects the operation economy of the unit. Through a test of a 1055t / h control circulating boiler reheater, the factors that affect the water quantity of the reheater are analyzed and analyzed, which provides reference for the design, operation and reconstruction of the same type of unit.