评价由有使用血糖监测带(BGMS)经验的病人及注册护士(RN_s)对 BGMS 的解释。将肉眼观察整条带和二等分 BGMS 的解释与反射计量仪所获得的读数相比较,对整条 BGMS,当病人解释的平均值与3个 RN_s 中的2个的解释及计量仪的读数相比较时,发现有明显的差异;第3个护士的解释和计量仪平均值之间亦有明显差异。对二等分 BGMS,发现计量仪读数与 BGMS 情况之间有明显的相互作用效果;当与整条 BGMS作对比时,注册护士系统地低估二等分 BGMS;而
To evaluate the interpretation of BGMS by patients and RNs who have experience with BGMS. The interpretation of the whole band and the bisected BGMS was visually compared to the readings obtained with the reflectometer, with the interpretation of the mean of the patient and the interpretation of 2 of the 3 RN_s and the reading of the meter for the entire BGMS Significant differences were noted when compared with the third nurse; there was also a significant difference between the interpretation of the third nurse and the mean of the meter. For bisected BGMS, there was a clear interaction between meter readings and BGMS; registered nurses systematically underestimated bisection BGMS when compared to the entire BGMS; and