1984年3月15日凌晨3:10许,丹阳县人民印刷厂拖蜡车间发生火灾,由于发现较晚,虽经消防队奋力扑救,仍造成直接损失2万7千余元。 火灾后,县公安局消防股立即进行了火灾原因调查。经调查、了解及现场勘查,发现起火部位在拖蜡槽处,从蜡槽旁的废墟中扒出电闸刀碎块一百余块,经拼接核对,确认其中有两把电源闸刀,处于合闸通电位置,至此,初步认定这起火灾原因是职工秦××在14日夜间12时下班时未切断蜡槽加温
As of 3:15 am on March 15, 1984, a fire broke out at the wax printing workshop of the People’s Printing Factory of Danyang County. As a result of the discovery, the Fire Department struggled to fight the blaze and caused a direct loss of more than 27,000 yuan. After the fire, the County Public Security Fire Department immediately conducted a fire investigation. After investigation, understanding and site survey, we found that the fire area was in the tow tank, and more than 100 blocks of electric knife were picked out from the rubble beside the wax tank. After stitching, it was confirmed that there were two power guns, Gate energized position, so far, initially identified the cause of the fire because the workers Qin × × at 14 o’clock on the 14th night when not working off the wax tank heating