1.暖风机不热东风_4型0082号机车,1985年入冬后司机反映热风机不热。检修车间认真地逐段检查了循环管路,并更换了热风机散热器,确认各部分状态良好。但机车在低手柄位运行时,热风机尚有些微热,而高手柄位时,热风机却成为冷风机,此时,热风机散热器的放气阀放不出水,手触在阀口处有向里吸气的感觉。连续两次定检均未查出原因。直到第二年2月,因柴油机水温高,查找原因时发现膨胀水箱通往高温水泵的补水管堵塞(补水管中间的橡胶管内层剥离所致)。更换胶管后水温高的问题获得解决,热风机不热的问题也意外地随之解
1. heater is not hot Dongfeng _4 0082 locomotive, after the winter 1985 drivers reflect the hot air heater is not hot. Check the workshop carefully paragraph by paragraph pipeline, and replaced the hot air radiator, to confirm that each part in good condition. However, locomotive running at low handle, the hot air heater is still slightly hot, but the high handle position, the hot air fan has become a cold air blower, this time, hot air blower radiator release valve can not put water, hand touch at the valve port Introverted feeling. Two consecutive seizure failed to detect the cause. Until February of the next year, because of the high water temperature of the diesel engine, it was found that the expansion pipe was blocked by the water supply pipe leading to the high-temperature water pump due to the reason of stripping the inner rubber tube in the middle of the water supply. After the replacement of the hose to solve the problem of high water temperature, hot air blower is also unexpected problem