本文分析了预处理-超滤-反渗透工艺处理大庆油田某地区地下水设备的运行情况,并对超滤与反渗透产水勾兑进行了研究,确定了最佳勾兑比例。目前该深度处理站已投入运行,超滤及反渗透产水的指标均完全达到设计要求,且系统运行稳定。经过该工艺处理后,超滤出水浊度≤0.1 NTU,SDI≤2,反渗透出水平均电导率小于15 ms/cm,除盐率均接近98.7%,反渗透回收率达到75%,超滤产水与反渗透产水2∶3勾兑后,水质各项指标均符合《生活饮用水卫生标准》(GB 5749—2006),并且主要水质指标远高于标准值。
This paper analyzes the pretreatment - ultrafiltration - reverse osmosis process of Daqing Oilfield groundwater equipment operation in a region, and the ultrafiltration and reverse osmosis water production blending has been studied to determine the best blending ratio. At present, the depth treatment station has been put into operation, ultrafiltration and reverse osmosis water indicators have fully met the design requirements, and the system is stable. After the process, the turbidity of the ultrafiltrated water is less than or equal to 0.1 NTU and the SDI is less than 2, the average conductivity of the reverse osmosis effluent is less than 15 ms / cm, the rate of desalination is close to 98.7%, and the reverse osmosis recovery rate reaches 75% Water and reverse osmosis water 2:3 After blending, the water quality indicators are in line with “drinking water health standards” (GB 5749-2006), and the main water quality indicators are much higher than the standard value.