论文部分内容阅读
本文根据同方向二台仪器各潮波的潮汐因子之比的离散程度,分析仪器对潮汐记录的一致性情况。 对金寨台二套金属水平摆倾斜仪一个月记录的调和分析结果表明,M_2、S_2、N_2、K_1和O_1五种主要潮波γⅠ/γⅡ平均值的相对误差南北分量为4.64%,东西分量为6.38%。与漳州台东西方向二台石英水平摆倾斜仪一个月记录调和分析结果比较,可以看出金属水平摆倾斜仪和石英水平摆倾斜仪对倾斜潮汐的记录具有相同水平的一致性。
In this paper, we analyze the consistency of the tide records according to the dispersion of the tidal factor ratios of the tidal waves of the two instruments in the same direction. The harmonic analysis of one month record of the metal horizontal pendulum inclinometer in Jinzhai station shows that the relative error of the average of γ Ⅰ / γ Ⅱ of the four main tidal waves M_2, S_2, N_2, K_1 and O_1 is 4.64% Is 6.38%. Compared with the one-month record reconciliation analysis results of two Taiwan quartz horizontal pendulum inclinometers in the west of Zhangzhou, we can see that the metal horizontal pendulum inclinometer and the quartz horizontal pendulum incontinuity have the same level of consistency with the records of the inclined tides.