6150_(c-2)型柴油机与ZMH56/24-6型直流电机配套,组成柴油直流脉冲发电机组。鉴于廿年来脉冲机组生产、调试情况,为了提高机组脉冲输出能量,即提高波形参数,缩短储能时间,采取提高柴油机最大空转转速,又加大柴油机每循环供油量来提高柴油机功率的办法,造成柴油机不完全燃烧,热负荷增加,排气管严重积炭,功率下降,迫使柴油机提前检修,因而直接影响着柴油机的经济性,可靠性和寿命。使这一装置不能发挥其应具有的技术性能。为探索这一问题,首先需讨论机组动态工况时,机组各装置的参数随转速,时间变化关系,如柴油机工作特性,电机输出波形,机组复合转动惯量储、放机组动能变化规律等,找出其相互间的关系,运用能量守恒定律,分析能量转换过程,得出能量平衡关系方程。要取得符合实际情况的运算,首先要取得较精确的测试数据和解决取得这些测试数据的试验方法。采用与机组配套的简单仪表仪器和机组设备,用简易的直接和间接的测试方法,测出较准确的数据。依据所得数据,通过计算,找出机组最佳配合参数,既能兼顾到脉冲波形,通电及断电间歇储能时间的要求和柴油机较好的燃烧,又不增大柴油机热负荷,从而使机组持久可靠的运转,使机组获得较好的配合,以发挥机组最佳技术性能。
6150_ (c-2) diesel engine and ZMH56 / 24-6-type DC motor package to form a diesel DC pulse generator. In view of the pulse unit production and commissioning in the past 20 years, in order to improve the pulse output energy of the unit, that is to increase the waveform parameters, shorten the storage time, and to increase the maximum idle speed of the diesel engine and increase the diesel engine oil supply per cycle to increase the power of the diesel engine, Resulting in incomplete combustion of diesel engine, increased heat load, exhaust pipe serious coke, power down, forcing diesel engine maintenance in advance, which directly affects the economy, reliability and life of the diesel engine. So that this device can not play its due technical performance. In order to explore this problem, we first need to discuss the dynamic conditions of the unit, the unit parameters of the unit with the speed, time changes, such as diesel engine operating characteristics, the motor output waveform, unit complex inertia, storage unit kinetic energy changes, find The relationship between them, the use of conservation of energy law, analysis of energy conversion process, draw the energy balance equation. To get in line with the actual situation of computing, we must first get more accurate test data and test methods to obtain these test data. The use of simple instrumentation equipment and equipment supporting units and units, with a simple direct and indirect test methods to measure more accurate data. Based on the obtained data, the optimal matching parameters of the generating unit can be found by calculation, which not only can meet the requirements of pulse waveform, intermittent power-on and power-off intermittent energy-storing time and better combustion of the diesel engine, but also can not increase the thermal load of the diesel engine, Durable and reliable operation, so that the crew get better coordination, in order to play the best technical performance unit.