红外探测器基本参数D~*标准化测量,测试系统中的黑体辐射应采用正弦调制器调制。正弦调制器可把辐射调制成真正的频率单一的正弦波,使其在系统中的传输不受电路频宽的影响,信号传输效率最高。这样测得的D~*参数才真实可靠。本文从调制器结构分析入手,引入传动比概念,照顾正弦光阑与调制盘的相配特性和电机的额定转速,设计为热释电探测器D~*测试所用的低频正弦调制器和PbS探测器时间常数测量所用的高频正弦调制器。给出了高低频正弦调制器的设计数据和结构图,以及PbS时间常数的测试结果。
Basic parameters of infrared detectors D ~ * standardized measurement, the blackbody radiation in the test system should be modulated with a sinusoidal modulator. Sine modulator can modulate the radiation into a single sine wave of true frequency so that its transmission in the system is not affected by the circuit bandwidth and the signal transmission efficiency is the highest. The D ~ * parameter measured in this way is true and reliable. This article starts with the analysis of the modulator structure, introduces the concept of gear ratio, takes care of the matched characteristic of the sine diaphragm and the modulation disk and the rated speed of the motor, and designs the low-frequency sine modulator and the PbS detector for the pyroelectric detector D ~ * test The high frequency sine modulator used for time constant measurement. The design data and structure of high and low frequency sinusoidal modulators and the test results of PbS time constant are given.