建立了地源热泵岩土换热器的简易数理模型 ,计算分析了竖直埋管的岩土换热器性能 ,并在重庆和上海两地进行了岩土换热器试验 ,发现短期运行参数与实验数据一致 ,长期连续运行性能参数小于实际值。计算分析和试验结果表明 ,岩土性能及由年平均温度决定的岩土原始温度对岩土换热器性能有显著影响。在砂岩中设置的换热器比沉积土中的性能好。岩土原始温度越低 ,换热器夏季的换热性能越强。综合考虑地质气候条件 ,上海、重庆两地都具有采用岩土换热器组建地源热泵的可行性 A simple mathematical model of ground-source heat pump rock-soil heat exchanger was established. The performance of rock-soil heat exchanger in vertical buried pipe was calculated and analyzed. The geothermal heat exchanger test was carried out in Chongqing and Shanghai. The short-term operating parameters Consistent with the experimental data, long-term continuous operation performance parameters less than the actual value. Computational analysis and test results show that the geotechnical properties and the original geotechnical temperature, which is determined by the annual mean temperature, have a significant impact on the performance of rock and soil heat exchangers. The heat exchanger set in the sandstone is better than the soil in the sediment. The lower the original temperature of geomaterials, the stronger the heat exchange performance in summer. Considering the geological and climatic conditions, both Shanghai and Chongqing have the feasibility of using geothermal heat exchangers to build geothermal heat pumps
其他文献
目的 针对神经内科护理文书书写中存在的问题进行讨论、总结,提出改进的管理措施,实行护理记录三级质控,持续性的质量改进,提高护理文书书写质量.方法 对神经内科2010年1月至
介绍了日本的一个水蓄冷空调系统的构成及运行情况,分析了实际运行数据,对系统进行了性能评价.指出该系统采用大温差蓄冷,具有减少水蓄冷槽占地、提高系统节能效果及不增加系
将燃气热水锅炉安装在18层住宅的楼顶,供暖系统采用闭式,上供下回、单管串并联形式.简要介绍了供暖系统和所用主要设备.运行与实测数据表明,该系统较节能,且具环保及安全性.
期刊
期刊
目的 对60名进入临床实习一个月的护生进行实习期的调查和分析,制定相应的带教方法,提高带教质量.方法 对60名护生采用发放调查表、召开座谈会和个别谈话相结合的方法进行调
对目前地板供暖中存在的地板表面发热量计算、房间热负荷、填充层最佳厚度、地板供暖与散热器供暖水系统共用热源、地板供暖配套的地面装修以及承压保温地面结构层等重要技术
期刊
旨在评估变压器的频率响应对于绕组变形的检测灵敏度,为频率响应法的判据提供理论依据.利用了变压器的集中参数模型,分析了模型中各元件的物理意义,同时利用该模型进行了部分
期刊