我厂两台SHL—20—13A型锅炉中,1~#炉1992年投入运行,在用分层给煤装置之前,为满足生产要求,经常超负荷运行。所用煤种发热量在18855kJ/kg左右,经常跑红火,煤渣可燃物有时超过40%,后边挡渣铁由于严重过烧,每年更换一次,甚至挡渣铁下部搁座都被烧坏,出渣机事故频繁,为了防止出渣机过烧,只能开大冷却水将红炭浸灭。煤闸板经常因为中断冷却水而烧坏,被迫停炉影响生产,成为制约生产的主要因素。自从1~#炉改为分层给煤装置后,效果比较明显。2~#炉是1994年投入运行的,两炉在煤种、煤层、计量器具及所带负荷18t/h的情况下作比较如表1:
I SHL-20-13A boiler two plants, 1 ~ # furnace put into operation in 1992, before using stratified coal feeding device, in order to meet the production requirements, often overloaded operation. Coal used in the heat of 18855kJ / kg or so, often run red, sometimes more than 40% of cinders combustibles, behind the slag iron due to severe over-burning, replaced once a year, and even block the lower slag iron are burned, the slag Machine frequent accidents, in order to prevent the slag machine over-burning, only open a large cooling water will be soaked in red charcoal. Coal baffle often because of interruption of cooling water and burn, was forced to shut down affect production, become the main factor restricting production. Since 1 ~ # furnace to stratified coal feeding device, the effect is more obvious. 2 ~ # furnace was put into operation in 1994, two furnaces in the coal, coal, measuring instruments and the load carried 18t / h for comparison as shown in Table 1: