利用钽丝作为热线的瞬态双热线系统对温度区间233-373K、压力区间为0.1—30 MPa的液相二乙二醇单甲醚(diethylene glycol monom ethylether,DGMME)的导热系数进行了实验研究,并将实验数据拟合为温度和压力的关联式。实验数据与导热系数关联式计算结果的标准偏差和最大偏差分别为0.23%和0.86%,导热系数的合成标准不确定度小于±1.0%。“,”The thermal conductivity of liquid diethylene glycol monomethyl ether (DEGMME) was measured from 233 to 373 K and pressures from 0.1 to 30 MPa, by the transient hot-wire technique employing two anodized tantalum hot wires. The experimental data was correl