论文部分内容阅读
目的:了解那坡县医疗卫生单位消毒情况,为提高消毒质量和加强监督提供依据。方法:根据《消毒技术规范》和《医院消毒卫生标准》,对使用中消毒液、灭菌医疗用品、紫外线灯强度、高压蒸汽灭菌、物体表面、医务人员的手和室内空气进行采样检测。结果:2006年-2011年合计检测样品2292份,总合格率为81.02%。使用中消毒液、灭菌医疗用品、紫外线灯强度、高压蒸汽灭菌、物体表面、医务人员手和室内空气的合格率分别为97.21%、96.11%、92.70%、81.22%、77.39%、71.33%和55.08%。结论:那坡县医疗机构消毒合格率偏低,但逐年提高,仍需加强监督与管理。
Objective: To understand the disinfection of Napo County medical and health units, to improve the quality of disinfection and to provide the basis for supervision. Methods: According to Disinfection Technical Code and Hospital Disinfection Sanitation Standard, sampling and testing were conducted on disinfectant, sterilized medical supplies, intensity of UV lamp, autoclaving, surface of objects, medical staff’s hands and indoor air. Results: From 2006 to 2011, a total of 2292 samples were tested, with a total pass rate of 81.02%. The passing rate of disinfectant, sterilized medical supplies, UV lamp intensity, autoclaving, surface of the object, medical staff and indoor air were 97.21%, 96.11%, 92.70%, 81.22%, 77.39%, 71.33% And 55.08%. Conclusion: Napo County medical institutions disinfection pass rate is low, but increased year by year, still need to strengthen supervision and management.