论文部分内容阅读
(续)柴油发电站的冷却水量约0.03~0.06 t/马力·h。当进出水的温差较小时取较大值。一般采用直流系统(受热后排弃),由本大楼供水管直供。柴油发电站的润滑油量约4 g/马力·h。至少应有20天的储存量。柴油发电站每台机组应各设一个排气管。排气管设于室外,离墙约1 m。排气管应有隔热消声措施。进气空气过滤器可在室内就地布置。柴油发电站内一般可不设起重设备。
(Continued) The amount of cooling water in a diesel power station is approximately 0.03 to 0.06 t/hp. When the temperature difference between the inlet and outlet water is small, take a larger value. DC systems are generally used (discarded after heat removal) and are supplied directly from the building’s water supply pipe. The amount of lubricating oil in diesel power stations is about 4 g/hp. There should be at least 20 days of storage. Each unit of a diesel power station shall have one exhaust pipe. The exhaust pipe is located outdoors, about 1 m from the wall. Exhaust pipe should have insulation muffler measures. The intake air filter can be placed in the room. Diesel power stations generally do not have lifting equipment.