论文部分内容阅读
上海市通用机械技术研究所和上海冷气机厂于八三年联合研制成功SHF—10W型风冷热回收恒温恒湿空气调节设备,并在十二月六日在上海冷气机厂通过鉴定。该设备是在原水冷式恒温恒湿装置的基础上把水冷式冷凝器改为风冷式冷凝器,并在蒸发器后面增设一个辅助冷凝器与室外主风冷凝器并联,利用制冷系统制冷时放出的热量通过辅助冷凝器排出的部分冷凝热再加热蒸发器出来的空气,这样就省去了原来的电加热器再加热空气所消耗的电能。
Shanghai General Machinery Research Institute and Shanghai Air-Conditioner Factory jointly developed SHF-10W air-cooled heat recovery constant temperature and humidity air conditioning equipment in 1993 and passed the appraisal in Shanghai Air Conditioner Factory on December 6. The device is based on the original water-cooled constant temperature and humidity device to the water-cooled condenser to air-cooled condenser and an auxiliary condenser behind the evaporator with the outdoor main air condenser in parallel, the use of refrigeration refrigeration system when released Of the heat through the auxiliary condenser part of the condensation heat and then reheat the evaporator air, thus eliminating the need for the original electric heater to reheat the air consumed by the energy.