论文部分内容阅读
目的:了解医疗机构消毒灭菌状况,确保奥运会消毒灭菌质量。方法:采用现场调查和采样检测方法,对医疗机构的空气、物体表面、医务人员手、紫外线灯、压力蒸汽灭菌器、使用中消毒剂及洁净手术室消毒灭菌效果进行评价。结果:空气质量、物体表面、紫外线灯、压力蒸汽灭菌器合格率为100%,医务人员手合格率为89.36%,使用中消毒剂合格率为88.24%,洁净手术室的菌落数合格率为87.5%,粒子数合格率为87.5%,压差合格率为62.5%,换气次数合格率为6.67%,温度合格率为62.5%,湿度合格率为31.25%。结论:奥运前医疗机构消毒灭菌工作总体较好,但部分工作有待提高。
Objective: To understand the status of disinfection and sterilization in medical institutions and to ensure the quality of disinfection and sterilization in Olympic Games. Methods: The effects of disinfection and sterilization on the surface of air, objects, medical staff, ultraviolet lamps, pressure steam sterilizer, disinfectant in use and clean operating room in medical institutions were evaluated by field survey and sampling. Results: The pass rate of air quality, object surface, UV lamp and pressure steam sterilizer was 100%, the pass rate of medical staff was 89.36%, the pass rate of disinfectant in use was 88.24%, the pass rate of clean operating room was 87.5%, the passing rate of particles was 87.5%, the pass rate of pressure difference was 62.5%, the pass rate of ventilation was 6.67%, the pass rate of temperature was 62.5% and the pass rate of humidity was 31.25%. Conclusion: The disinfection and sterilization of medical institutions before the Olympic Games is generally good, but some of the work needs to be improved.