论文部分内容阅读
问GB 50057—2010《建筑物防雷设计规范》已经于2011年10月1日起实施,和GB 50057—1994(2000年版)相比,规范条文变化很大。自新版防雷规范实施后,从送审施工图纸看,太阳能热水器的防雷做法大致分为两种:一种是不做太阳能热水器专用接闪器,仅将热水器钢结构支架和屋面防雷装置连接;另外一种做法是专门为太阳能热水器设置接闪器,并和屋面防雷装置连接(如图1所示)。
Ask GB 50057-2010 “Lightning Protection Design Code for Buildings” has been implemented since October 1, 2011, and GB 50057 - 1994 (2000 version), the provisions of the norms vary greatly. Since the implementation of the new version of lightning protection norms, from the draft construction drawings, solar water heater lightning protection practices are broadly divided into two types: one is not for solar water heater dedicated lightning receptor, only the water heater steel structure bracket and roof lightning protection device ; Another approach is specifically for the solar water heater lightning receptor, and the roof lightning protection device connection (Figure 1).