在悬臂梁弯曲振动模式下,使用磁激发振动杆、静电感应接收、直接放大讯号的方法,测量了薄至59μm非晶态磁性合金薄带的杨氏模量,以及18μm非晶态恒弹性合金薄带室温至正100℃频率温度系数。真空度可达2.6×10~(-3)Pa。温度范围为室温至正200℃。条件试验表明,共振频率随激发电压、直流偏压的增加而减小,随试样有效长度的减小而降低,从而使杨氏模量降低。
In the bending vibration mode of cantilever beam, the Young’s modulus of thin amorphous magnetic alloy ribbons up to 59μm was measured by means of magnetically excited vibrating rod, electrostatic induction receiving and direct amplification of signal, and 18μm amorphous constant elastic alloy thin With room temperature to positive 100 ℃ frequency temperature coefficient. The degree of vacuum can reach 2.6 × 10 ~ (-3) Pa. The temperature range is from room temperature to plus 200 ° C. The experimental results show that the resonance frequency decreases with the increase of the excitation voltage and the DC bias, decreases with the decrease of the effective length of the sample, and decreases the Young’s modulus.