论文部分内容阅读
本文在分析影响辐射管集水因素的基础上,通过模拟试验及对模拟试验数据进行回归分析计算结果,得出了集取河床渗透水的辐射管集水计算模型。并经引用工程实例中的生产性试验数据对该模型进行的验证,其精度能满足实际工程的要求。
Based on the analysis of the factors influencing the catchment of radiant tubes, the calculation model of radiant tube catchment for collecting seepage water from the riverbed is obtained through the simulation test and regression analysis and calculation of simulation test data. The model is validated by the production test data in the project example. The accuracy of the model can meet the requirements of the actual project.