论文部分内容阅读
摘要:近年来,随着我国城市化的不断发展,城市土地面积日趋紧张,从而导致城市的住宅逐渐向高层建筑发展。与此同时随之而来的电梯供电、家用电器多样化等问题都需要进行详尽的设计与施工。所以高层住宅的电气设计逐渐成为建筑领域的关键课题。本文在此从电气设计的问题出发,先对高层住宅的负荷等级及负荷计算做了初步的研
究,并探讨了电气设计过程中应该注意的几个要点。
关键词:电气;设计;问题
Abstract: In recent years, along with our country the ceaseless development, city land area is intense with each passing day, resulting in city residential gradually to the development of high rise building. At the same time the elevator power supply, household appliances diverse issues such as the need for detailed design and construction. Therefore, high-rise residential electrical design has gradually become the key issues in construction field. This paper from the electrical design problems, first the high-rise residential load levels and load calculation to do a preliminary study, and discusses the electrical design process should pay attention to several points.
Key words: electric; design; problem
中图分类号:TU2
前言:工程设计是基本建设的龙头,设计文件是工程建设的主要依据,设计质量是决定工程质量的首要环节。我国工程质量事故统计资料显示,由设计原因导致的工程质量事故占40.1%;工程施工原因引起的占29.3%;其它原因(如设备材料质量问题等)引起的占30.6%。因此做好建筑电气设计意义重大。
一、现代建筑电气设计存在的问题分析
1、某些旧住宅在进行配电改造设计时,采用直敷布线,当导线垂直敷设时,未经任何保护就进入距地1.4m 的明装照明开关。不符合现行国家标准《低压配电设计规范》GB50054—95 的第 5.2.1 条第3 款“当导线垂直敷设至地面低于1.8m 时,应穿管保护”的规定。
2、暗敷线路按最近路线敷设时,由于住宅的面层比较薄,线路管线交叉不易处理;另外照明线路通常利用顶棚灯的接线盒进线分线,在住户铺设木地板时,往往将敷设在地坪内的管线打断,造成电气不安全和使用的不方便。暗敷线路沿板孔、墙缝垂直或平行于地面敷设,就可以避免上述问题的发生,因为管线交叉可以在墙缝中解决,而照明线路则在墙的拐弯处利用接线盒进行分线,而非顶棚灯的接线盒,这样住户也可根据《住宅使用说明书》中的配电平面图,了解进入灯具线路的具体方向和位置,从而避免在铺设木地板时将管线打断。
3、目前,住宅设计大量选用模数化配电箱,其中大部分型号是PZ30,但PZ30 是不应该在住宅中使用的。因为PZ30和PZ20是同时开发的两个系列,分别按两种使用场合设计的,PZ20按非熟练人员场合设计,主要用于家庭和类似场所; PZ30则按熟练人员使用设计,主要用于工业场所。因此,只要电气间隙爬电距离足够,很多三相系统PZ20能代替PZ30系列。由此可见,PZ30不应在住宅中使用。
二、高层住宅负荷等级及负荷计算
高层住宅的负荷主要有三个等级,分别是以应急照明用电、消防用电为主的一级负荷,以公用电梯用电、公用照明用电为主的二级负荷以及以居民用电为主的三级负荷。对于新时期的高层住宅而言,一级负荷和二级负荷都是存在的,所以供电电源最后需要有独立的两个供电回路。三级负荷由于是以居民用电为主,所以对于供电的要求并不高,只需要一路的供电电源即可。在进行电气设计时,要考虑供电系统的配置维修简易性,尽量减少配电级数。
当高层住宅的负荷等级确定以后,然后进行电力负荷的计算,这是高层住宅的电气设计的依据。准确的电力负荷计算,对于电气设备的选型及安全运行都起到非常重要的作用。新时期高层住宅的电气设计要遵循“以人为本”的原则,不仅要保证经济、安全、美观等要求,还要突出新时期高层住宅的特点,在经济条件保障的前提下,适当的将电气设计的起点提高,尽可能的体现一定的时代超前性,将新材料、新工艺、新产品合理的应用其中,提高新时期住宅的技术含量,尽量满足人们对于新时期住宅多用途的功能增长需求。
三、新时期高层住宅电气设计应注意的几个方面
1、配电系统的设计方面
要想使得高层住宅保证供电安全正常,配电系统的设计成功是一个重要的保证。一个稳定且可靠的配电系统,是住宅建筑电气系统功能发挥的关键。不同电压的配电系统,采用的配电方式不同,例如10KV的供电系统最好采用的是环网方式,对于220/380V 配电系统应该采用树干式的方式,新时期的高层住宅最好保留备用的回路系统。
2、主要电气设备的选型
新时期高层住宅中所有的电气设备主要有:电表、配电箱、开关等,对于高层住宅来讲,电气设备选型工作非常重要,合理的选择电气设备对于一项高质量、高水平的高层住宅必不可少,電气设备的选型不能随意为之,而是受到许多条件的影响,例如住宅的总体电力负荷情况、电气设备安装和使用环境以及工作电压等等,这些条件在高层住宅的电气设备的选型工作中是必须要考虑的,只有这样才能选择出合适的电气设备型号。一般来讲,电气设备的容量既不能过大,也不能过小,因为过大的容量容易造成浪费,过小的容量又不够安全。
3、新时期高层住宅建筑室内线路问题
当前,大多数住宅建筑的交房标准都是毛坯房,在施工图纸中,所有的照明、插座、电视等线路都设计的非常清楚,必须按照施工图纸敷设到位,当业主入住后,除却一小部分的照明线路以外,大多数进行再次装修时,室内线路几乎全部要重新敷设,新时期住宅楼的面层大多比较薄,且线路管线交叉,当住户入住以后进行二次装修时,经常要将地坪内敷设的室内线路打断,这不符合高层住宅电气设计初衷,且容易产生电气安全隐患,从而可能导致电气事故的发生。但是实际上,在墙缝中可以将管线交叉的问题解决,线路可以沿着地板孔、墙缝平行或垂直于地面的方向敷设,这样的话就完全可以避免管线交叉的问题。
4、防雷与接地
现代高层建筑的防雷设计,除采用避雷针和避雷带的传统做法外,近年还出现有消雷器和放射性避雷针。这两种防雷技术虽然在工程上得到不少实际应用,但在理论上一直是有争议的。现代高层建筑都是采用钢筋混凝土剪力墙,与楼板的连接是十分可靠的。关键是做好金属管线的接地。
现代高层建筑的防雷接地、电气设备的保护接地和工作接地,都是合在一起的,组成混合接地系统。接地电阻按最小的要求而定,通常是在4欧以下。利用建筑物的钢筋混凝土基础作接地板。尽管基础钢筋等自然接地体已能满足接地电阻的要求,仍需要装设水平的人工接地体,将主要的建筑物基础连接成接地网,这对均衡电位,提高安全性都有好处。
5、电梯
电梯机房一般设置在井道上面。普通电梯的梯井可连通或设开口相连通。电梯按使用功能分,普通电梯、消防电梯等许多种;按速度又分为低速梯、快速梯、高速梯和超高速梯等;按电流分则有交流和直流两大类。现代高层建筑的电梯,为了提高输送能力和缩短候梯时问,一般都采用高速或超高速电梯,分组实行电脑群控。为提高运行的稳定性和舒适感,客梯都是选用直流电动机驱动。在进行电梯设计时一定要做好配电设计、主开关选择、电气照明、通风装置和插座设置及控制等相关问题。
6、消防自动报警和自动灭火系统
现代高层建筑的火灾自动报警灭火系统,包括:火灾探测器、分区消防报警控制器、消防中心和气体自动喷射灭火及自动洒水灭火系统等四个部分,实现报警灭火自动化。探测器探测到火灾信号后转换成电信号,进人分区报警器和消防中心,发出声光报警信号。消防中心负责整座大楼火灾的监控和消防指挥。关于高层建筑中消防用电的设计问题,涉及到其他许多学科,而且规模越大,功能越多,控制内容越广泛,设计内容也就越复杂。
四.总结
综上所述,建筑电气设计作为建筑设计最重要的一个环节。应在设计中精心考虑。但是在选用节能的新设备上,应具体了解其原理、性能、效果,从技术、经济上进行比较后,再选定节能设备,并且综合考虑线路、防雷及电梯等综合因素,以达到真正节能的目的。
参考文献:
【1】许琳. 高层建筑电气设计的主要内容及节能原则. 黑龙江科技信息[J].2007(5):207
【2】住宅设计规范 GB50096- 1999 (2003年版)
【3】叶玄菊.高层住宅电气设计刍议,建筑设计[J].2008(02).
究,并探讨了电气设计过程中应该注意的几个要点。
关键词:电气;设计;问题
Abstract: In recent years, along with our country the ceaseless development, city land area is intense with each passing day, resulting in city residential gradually to the development of high rise building. At the same time the elevator power supply, household appliances diverse issues such as the need for detailed design and construction. Therefore, high-rise residential electrical design has gradually become the key issues in construction field. This paper from the electrical design problems, first the high-rise residential load levels and load calculation to do a preliminary study, and discusses the electrical design process should pay attention to several points.
Key words: electric; design; problem
中图分类号:TU2
前言:工程设计是基本建设的龙头,设计文件是工程建设的主要依据,设计质量是决定工程质量的首要环节。我国工程质量事故统计资料显示,由设计原因导致的工程质量事故占40.1%;工程施工原因引起的占29.3%;其它原因(如设备材料质量问题等)引起的占30.6%。因此做好建筑电气设计意义重大。
一、现代建筑电气设计存在的问题分析
1、某些旧住宅在进行配电改造设计时,采用直敷布线,当导线垂直敷设时,未经任何保护就进入距地1.4m 的明装照明开关。不符合现行国家标准《低压配电设计规范》GB50054—95 的第 5.2.1 条第3 款“当导线垂直敷设至地面低于1.8m 时,应穿管保护”的规定。
2、暗敷线路按最近路线敷设时,由于住宅的面层比较薄,线路管线交叉不易处理;另外照明线路通常利用顶棚灯的接线盒进线分线,在住户铺设木地板时,往往将敷设在地坪内的管线打断,造成电气不安全和使用的不方便。暗敷线路沿板孔、墙缝垂直或平行于地面敷设,就可以避免上述问题的发生,因为管线交叉可以在墙缝中解决,而照明线路则在墙的拐弯处利用接线盒进行分线,而非顶棚灯的接线盒,这样住户也可根据《住宅使用说明书》中的配电平面图,了解进入灯具线路的具体方向和位置,从而避免在铺设木地板时将管线打断。
3、目前,住宅设计大量选用模数化配电箱,其中大部分型号是PZ30,但PZ30 是不应该在住宅中使用的。因为PZ30和PZ20是同时开发的两个系列,分别按两种使用场合设计的,PZ20按非熟练人员场合设计,主要用于家庭和类似场所; PZ30则按熟练人员使用设计,主要用于工业场所。因此,只要电气间隙爬电距离足够,很多三相系统PZ20能代替PZ30系列。由此可见,PZ30不应在住宅中使用。
二、高层住宅负荷等级及负荷计算
高层住宅的负荷主要有三个等级,分别是以应急照明用电、消防用电为主的一级负荷,以公用电梯用电、公用照明用电为主的二级负荷以及以居民用电为主的三级负荷。对于新时期的高层住宅而言,一级负荷和二级负荷都是存在的,所以供电电源最后需要有独立的两个供电回路。三级负荷由于是以居民用电为主,所以对于供电的要求并不高,只需要一路的供电电源即可。在进行电气设计时,要考虑供电系统的配置维修简易性,尽量减少配电级数。
当高层住宅的负荷等级确定以后,然后进行电力负荷的计算,这是高层住宅的电气设计的依据。准确的电力负荷计算,对于电气设备的选型及安全运行都起到非常重要的作用。新时期高层住宅的电气设计要遵循“以人为本”的原则,不仅要保证经济、安全、美观等要求,还要突出新时期高层住宅的特点,在经济条件保障的前提下,适当的将电气设计的起点提高,尽可能的体现一定的时代超前性,将新材料、新工艺、新产品合理的应用其中,提高新时期住宅的技术含量,尽量满足人们对于新时期住宅多用途的功能增长需求。
三、新时期高层住宅电气设计应注意的几个方面
1、配电系统的设计方面
要想使得高层住宅保证供电安全正常,配电系统的设计成功是一个重要的保证。一个稳定且可靠的配电系统,是住宅建筑电气系统功能发挥的关键。不同电压的配电系统,采用的配电方式不同,例如10KV的供电系统最好采用的是环网方式,对于220/380V 配电系统应该采用树干式的方式,新时期的高层住宅最好保留备用的回路系统。
2、主要电气设备的选型
新时期高层住宅中所有的电气设备主要有:电表、配电箱、开关等,对于高层住宅来讲,电气设备选型工作非常重要,合理的选择电气设备对于一项高质量、高水平的高层住宅必不可少,電气设备的选型不能随意为之,而是受到许多条件的影响,例如住宅的总体电力负荷情况、电气设备安装和使用环境以及工作电压等等,这些条件在高层住宅的电气设备的选型工作中是必须要考虑的,只有这样才能选择出合适的电气设备型号。一般来讲,电气设备的容量既不能过大,也不能过小,因为过大的容量容易造成浪费,过小的容量又不够安全。
3、新时期高层住宅建筑室内线路问题
当前,大多数住宅建筑的交房标准都是毛坯房,在施工图纸中,所有的照明、插座、电视等线路都设计的非常清楚,必须按照施工图纸敷设到位,当业主入住后,除却一小部分的照明线路以外,大多数进行再次装修时,室内线路几乎全部要重新敷设,新时期住宅楼的面层大多比较薄,且线路管线交叉,当住户入住以后进行二次装修时,经常要将地坪内敷设的室内线路打断,这不符合高层住宅电气设计初衷,且容易产生电气安全隐患,从而可能导致电气事故的发生。但是实际上,在墙缝中可以将管线交叉的问题解决,线路可以沿着地板孔、墙缝平行或垂直于地面的方向敷设,这样的话就完全可以避免管线交叉的问题。
4、防雷与接地
现代高层建筑的防雷设计,除采用避雷针和避雷带的传统做法外,近年还出现有消雷器和放射性避雷针。这两种防雷技术虽然在工程上得到不少实际应用,但在理论上一直是有争议的。现代高层建筑都是采用钢筋混凝土剪力墙,与楼板的连接是十分可靠的。关键是做好金属管线的接地。
现代高层建筑的防雷接地、电气设备的保护接地和工作接地,都是合在一起的,组成混合接地系统。接地电阻按最小的要求而定,通常是在4欧以下。利用建筑物的钢筋混凝土基础作接地板。尽管基础钢筋等自然接地体已能满足接地电阻的要求,仍需要装设水平的人工接地体,将主要的建筑物基础连接成接地网,这对均衡电位,提高安全性都有好处。
5、电梯
电梯机房一般设置在井道上面。普通电梯的梯井可连通或设开口相连通。电梯按使用功能分,普通电梯、消防电梯等许多种;按速度又分为低速梯、快速梯、高速梯和超高速梯等;按电流分则有交流和直流两大类。现代高层建筑的电梯,为了提高输送能力和缩短候梯时问,一般都采用高速或超高速电梯,分组实行电脑群控。为提高运行的稳定性和舒适感,客梯都是选用直流电动机驱动。在进行电梯设计时一定要做好配电设计、主开关选择、电气照明、通风装置和插座设置及控制等相关问题。
6、消防自动报警和自动灭火系统
现代高层建筑的火灾自动报警灭火系统,包括:火灾探测器、分区消防报警控制器、消防中心和气体自动喷射灭火及自动洒水灭火系统等四个部分,实现报警灭火自动化。探测器探测到火灾信号后转换成电信号,进人分区报警器和消防中心,发出声光报警信号。消防中心负责整座大楼火灾的监控和消防指挥。关于高层建筑中消防用电的设计问题,涉及到其他许多学科,而且规模越大,功能越多,控制内容越广泛,设计内容也就越复杂。
四.总结
综上所述,建筑电气设计作为建筑设计最重要的一个环节。应在设计中精心考虑。但是在选用节能的新设备上,应具体了解其原理、性能、效果,从技术、经济上进行比较后,再选定节能设备,并且综合考虑线路、防雷及电梯等综合因素,以达到真正节能的目的。
参考文献:
【1】许琳. 高层建筑电气设计的主要内容及节能原则. 黑龙江科技信息[J].2007(5):207
【2】住宅设计规范 GB50096- 1999 (2003年版)
【3】叶玄菊.高层住宅电气设计刍议,建筑设计[J].2008(02).