论文部分内容阅读
目的探讨影响呼吸机螺纹管消毒效果的因素,进一步规范操作规程,提高工作质量。方法采用对消毒后备用的呼吸机螺纹管30套,进行消毒效果监测。结果 27套呼吸机管路消毒合格,合格率为90%,未检出致病菌,达到卫生学标准。结论使用科室擅自处理用后的呼吸机螺纹管、清洗槽用后未作消毒处理、自行缩短干燥时间等违反操作规程因素,均可导致呼吸机螺纹管的清洗消毒失败。
Objective To explore the factors influencing the disinfection effect of the screw thread tube of ventilator to further regulate the operation rules and improve the quality of work. Methods Thirty sets of ventilator thread tubes for disinfection were used to monitor the disinfection effect. Results 27 sets of ventilator pipeline disinfection, passing rate of 90%, did not detect pathogens, meet the hygiene standards. Conclusion The use of department without the use of ventilator thread tube, cleaning tank without disinfection, shorten the drying time on their own violation of rules and other factors, can lead to ventilator thread cleaning and disinfection failed.