Use of the Attain Select Ⅱ catheter delivery system to improve left ventricular lead implantation in

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:fanny_lizzy
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background Despite technical advances in tools used to facilitate implantation of cardiac resynchronization therapy (CRT) devices, there are many hurdles related mainly to the variation in the anatomy of the coronary veins. One such difficulty is the presence of a very sharply-angulated or tortuous of the lateral or posterolateral cardiac vein.Methods Totally 44 patients, 28 males and 16 females, with congestive heart failure and intraventricular conduction delay were studied retrospectively. There were 23 patients who had left ventricular (LV) lead implantation using standard techniques and equipment. For the other 21 patients with LV lead implantation we used the Attain Select Ⅱ catheter delivery system. The patients were seen every 3-6 months for 12 months and the efficacy of the primary procedure, LV lead implantation time, procedure and fluoroscopy time and the complications associated with the two techniques were evaluated.Results There were no significant differences in the age, gender, New York Heart Association (NYHA) functional class,ischemic etiology, QRS duration, left ventricular ejection fraction, left ventricular end-diastolic diameter, left ventricular end-systolic diameter and LV dyssynchrony between the two groups. The LV lead implantation time, procedure time and fluoroscopy time were significantly shorter in the group using the Attain Select Ⅱ catheter delivery system; LV lead implantation time from (51-7) minutes to (40±7) minutes (P <0.001), procedure time from (143±17) minutes to (124±18)minutes (P=0.001), and fluoroscopy time from (45±7) minutes to (35±6) minutes (P<0.001). A successful procedure of LV lead implantation was significantly improved from 17/23 (74%) patients using the standard techniques and equipment, to 20/21 (95.3%) patients using the Attain Select Ⅱ catheter delivery system (P=0.06)Conclusion It is feasible and safe to implant LV leads through the coronary sinus using the Attain Select Ⅱ catheter delivery system.
其他文献
文章在系统地总结空间粉尘(微小空间碎片和微流星体)探测技术的基础上,重点分析了压电型探测器、半导体型探测器、电离型探测器、组合式探测器等的工作原理、技术特点及其应
Objective To evaluate immunologic mechanisms underlying Aspergillus fumigatus pulmonary infections in immunocompetent Dark Agouti(DA) and Albino Oxford(AO) rats
Objective To study the risk environmental and psycho-social factors associated to prostate cancer (PCa) in Chinese population. Methods 250 PCa patients and 500
The occurrence of foreign body is uncommon in youths and adults. We report here a case of 16-year-old boy who inhaled a foreign body which was overlooked for 6
Circular cylinder separation control and flow structure influenced by the synthetic jet have been experimentally investigated in a water channel. The synthetic
Background Indoleamine-2,3-dioxygenase (IDO) is proven to suppress hepatitis B virus (HBV) specific immune response and depletion of IDO may be a useful approa
Background Studies indicated that Mer might be the main contributor to the specific internalization of photoreceptor outer segments (POS) in retinal pigment epi
Background The mammalian target of rapamycin (mTOR) pathway, a key cellular signaling pathway associated with various cellular functions, has distinct roles in
Background Cytomegalovirus (CMV) retinitis is the most severe intraocular complication that results in total retinal destruction and loss of visual acuity in pa