Standard-sample bracketing calibration method combined with Mg as an internal standard for silicon i

来源 :Acta Geochimica | 被引量 : 0次 | 上传用户:kiddmanwy
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Silicon isotope analysis traditionally uses a standard-sample bracketing(SSB) method that relies upon greater instrument stability than can be consistently expected. The following proposed method reduces the level of instrumental stability required for the analysis process and provides a valid solution for high-precision and accurate studies of Si isotopic compositions. Rock samples were dissolved by using alkali fusion and acidification.Silicon isotopes were purified with an ion exchange resin.Interfering peaks for isotopes were separated by using a Nu Plasma 1700 multi-collector inductively coupled plasma mass spectrometry(MS) system in high-resolution mode(M/DM [ 8000 RP). Two magnesium isotopes(~(25)Mg and~(26)Mg) and three silicon isotopes(~(28)Si,~(29) Si, and~(30)Si) were analyzed in the same data collection cycle. Mg isotopes were used as an internal standard to calibrate the mass discrimination effects in MS analysis of Si isotopes in combination with the SSB method in order to reduce the effects of MS interference and instrumental mass discrimination on the accuracy of measurements. The conventional SSB method without the Mg internal standard and the proposed SSB method with Mg calibration delivered consistent results within two standard deviations.When Mg was used as an internal standard for calibration,the analysis precision was better than 0.05 % amu. Silicon isotope analysis traditionally uses a standard-sample bracketing (SSB) method that relies upon greater instrument stability than can be consistently expected. The following proposed method reduces the level of instrumental stability required for the analysis process and provides a valid solution for high-precision and accurate studies of Si isotopic compositions. Rock samples were dissolved by using alkali fusion and acidification. Silicon isotopes were purified with an ion exchange resin. Interfering peaks for isotopes were separated by using a Nu Plasma 1700 multi-collector inductively coupled plasma mass spectrometry MS) system in high-resolution mode (M / DM [8000 RP). Two magnesium isotopes (25 Mg and 26 Mg) and three silicon isotopes and ~ (30) Si) were analyzed in the same data collection cycle. Mg isotopes were used as an internal standard to calibrate the mass discrimination effects in MS analysis of Si isotopes in combination with the SSB method in order t o reduce the effects of MS interference and instrumental mass discrimination on the accuracy of measurements. The conventional SSB method without the Mg internal standard and the proposed SSB method with Mg calibration delivered the results within two standard deviations. for calibration, the analysis precision was better than 0.05% amu.
其他文献
随着社会主义市场经济体制的逐步完善,加快建立、完善与之相适应的社会保障体系,已经迫在眉睫。但是,什么是既适合中国国情又能与国际接轨,既解决当前现实问题又结合未来长
网络多媒体辅助英语教学易于激发学生兴趣,促使学生乐于学。使抽象的教学内容变具体,让学生易于学。创造真实情景,让学生在体验中学。提供自由拓展知识的空间,让学生自主学。
伴随着全球市场经济一体化的发展进步,各国之间的贸易交流逐渐增多,市场对于英语人才的需求量逐步增大。鉴于英语教育受到传统教学思维的限制,英语教学成效并不突出,学生过分
螺旋藻藻粉经热水抽提 ,乙醇沉淀 ,Sevag法去蛋白质 ,十六烷基三甲基溴化铵 (CTAB)沉淀得酸性杂多糖 ,再经 DEAE-纤维素柱层析分级纯化两次得多糖 PSP1 和 PSP2 。 PSP1 和 P
我国是世界上老龄人口绝对数最多的国家,又是世界上人口老龄化最快的国家之一。社会老化日趋严重,人口老化带来一系列问题,其中老年医疗保健尤为引人注目。本文就积极开展老
某公司总经理专车公出,司机有事来找。当时总经理正忙于工作,只是随意应答了几句,连头也没抬。司机不高兴地说:“你这态度不好。不要把自己弄得太忙,应该留些时间给自己思考。”这
从细梗香草 Lysimachia capillipes中分得 8个化合物 ,经光谱 (IR,MS,1 H,1 3CNMR,1 H- 1 HCOSY,1 H- 1 3CCOSY,HMBC)解析 ,鉴定了 2个新化合物 :香草内酯 ( )和香草素 ( )以
广东顺德市德冠双轴拉伸薄膜有限公司研发的BOPP抗菌防霉包装薄膜已顺利投入生产。该产品具有优异的抗菌防霉功效 ,对金黄色葡萄菌及大肠杆菌的抑菌率均超过 99.9% ,防霉等级
目前,每一个村委会年年都要订阅多种报刊,但不少地方的村里,报刊不是被堆积在村委会浪费,就是放在个别村干部家里“沉睡”。这些报刊最后都到了收破烂者的手中,群众难得一见
我科从1995年上半年开始,进行内部管理体制改革,现将做法及体会介绍如下: 1 基本举措 1.1 取消临床检验室,将其分为四组 血液组:门诊及病房血常规、血液流变、血细胞、出凝