论文部分内容阅读
本文介绍了一种基站配置改进方案,通过该方案可以在不增加基站成本的前提下,提高基站的利用率。通过这种方法可以将一个定向S111基站作为S11+O1、O1+O1+O1两个或三个基站使用,当然机柜站与另外两个模块站之间最大距离不能超过13KM。通过更换多载波模块MFRM最大可将S333基站改造成:S33+O3、O3+O3+O3。在基站机柜侧增加一个DCG组(CM和CORE)模块,最大可将一个基站作6个全向基站使用。其组合方式有:S111+O1、S111+S11、S111+S111、S111+O1+O1+O1、S111+S11+O1等。
This paper introduces a base station configuration and improvement program, through which the base station utilization can be improved without increasing the base station cost. In this way, one oriented S111 base station can be used as two or three base stations of S11 + O1, O1 + O1 + O1. Of course, the maximum distance between the cabinet station and the other two module stations can not exceed 13KM. By replacing the multi-carrier module MFRM up to S333 base station can be transformed into: S33 + O3, O3 + O3 + O3. Add a DCG group (CM and CORE) module on the base station cabinet side to make a maximum of 6 omnidirectional base stations for one base station. The combinations are: S111 + O1, S111 + S11, S111 + S111, S111 + O1 + O1 + O1, S111 + S11 + O1 and the like.