在实践中,我们使用下列方法保存甘汞电极。用时方便,检验结果不受影响,特介绍于下:即在浸泡玻璃电极的小烧杯(50ml)中;加放一个平底、高5cm、直径1.5cm的玻璃小管(或采用其他材料,只要与氯化钾不起化学反应即可)。内盛氯化钾的过饱和溶液,每次使用完毕后,将二电极用蒸馏水洗干净,将甘汞电极插入装有氯化钾过饱和溶液的小管中;玻璃电极同时浸在盛蒸馏水的烧杯中。用时,将二电极取出用蒸馏水冲洗干净,用搽镜纸或其他软料吸去附着的水分后,即可放在标准缓冲液中备用,随后洗净除水再测供试品。整个操作完成后,洗净并依上法保养。
In practice, we use the following methods to preserve the calomel electrode. The use of time is convenient, the test result is not affected, it is introduced in the following: namely in a small beaker (50ml) soaked glass electrode; add a flat bottom, height 5cm, diameter 1.5cm glass tube (or use other materials, as long as with chlorine Potassium does not have a chemical reaction.) The supersaturated potassium chloride solution was used. After each use, the second electrode was washed with distilled water. The calomel electrode was inserted into a small tube containing a potassium chloride supersaturated solution; the glass electrode was immersed in a beaker containing distilled water. in. When used, take out the two electrodes and rinse them with distilled water. After removing the attached moisture with lens paper or other soft materials, put them in the standard buffer for later use, then wash the water and then test the samples. After the entire operation is completed, wash it and follow the instructions.