为了解我区预防接种室局部消毒的质量和微环境污染状况,对我区街道和村的预防注射室消毒及污染情况进行了调查。其中酒精消毒液浓度、染菌量和空气、操作台面、手染菌量合格率分别为37.5%、36.6%、38.1%、68.3%、43.2%.街道卫生院的酒精消毒液浓度、台面和手染菌量合格率高于村卫生室;酒精和空气染菌量街道卫生院和村卫生室两级单位无明显差别。一次性注射器无菌试验合格率为100%.调查结果表明,我区预防注射室的消毒质量不高,环境污染比较严重。本文分析了原因,提出了改进建议。
In order to understand the quality of vaccination room disinfection and micro-environmental pollution in our district, we investigated the disinfection and pollution prevention of injection rooms in streets and villages in our district. The pass rate of alcohol disinfectant solution, bacteria and air, operation tabletop and hand-stained bacteria were 37.5%, 36.6%, 38.1%, 68.3% and 43.2% respectively. The concentration of alcohol disinfectant, tabletop and hand-stained bacteria in street hospitals were higher than those in village clinics. There was no significant difference between alcoholic and air-stained street hospitals and village clinics. Disposable syringe sterile test pass rate of 100%. The survey results show that the disinfection quality of injection prevention room in our district is not high and the environmental pollution is serious. This article analyzes the causes and puts forward suggestions for improvement.