简介了烟烙尽气体灭火的特点。介绍了烟烙尽气体灭火系统在吴泾电厂八期 60 0 MW机组集控楼中的保护区域设置和系统方案 ;自动控制、手动控制和应急操作 3种系统控制方式 ,此灭火系统对建筑物、空调系统、火灾报警系统的要求 ;以及灭火系统的安装情况和试压试验情况
Brief introduction of the charcoal gas fire extinguishing characteristics. This paper introduces the protection zone setting and system scheme of the COG extinguishing system in the control tower of the 80th phase of Wujing Power Plant’s 80th phase. The automatic control, manual control and emergency operation are three kinds of system control methods. Air conditioning system, fire alarm system requirements; and fire extinguishing system installation and pressure test conditions