论文部分内容阅读
A new method for the determination of atrazine,simazine and prometryn in water samples by on-line sweeping concentration technique in miceUar electrokinetic chromatography (MEKC) was developed.Various parameters affecting sample enrichment and separation efficiency were systematically studied.Compared with the conventional MEKC method,up to 60-200-fold improve- ment in concentration sensitivity was achieved in terms of peak height by using this sweeping injection technique.The compound strychnine was used as the internal standard for the improvement of the experimental reproducibility.The limits of detection (S/ N=3:1) for atrazine,simazine and prometryn were 9,10 and 0.5 ng mL~(-1),respectively.This method has been successfully applied to the analysis of atrazine,simazine and prometryn in lake,steam and ground water.
A new method for the determination of atrazine, simazine and prometryn in water samples by on-line sweeping concentration technique in mice Uar electrokinetic chromatography (MEKC) was developed. Variety parameters affecting sample enrichment and separation efficiency were systematically studied. Compared with the conventional MEKC method , up to 60-200-fold improve- ment in concentration sensitivity was achieved in terms of peak height by using this sweeping injection technique. The compound strychnine was used as the internal standard for the improvement of the experimental reproducibility. limits of detection ( S / N = 3: 1) for atrazine, simazine and prometryn were 9,10 and 0.5 ng mL ~ (-1) respectively. This method has been successfully applied to the analysis of atrazine, simazine and prometryn in lake, steam and ground water.