Diver CE versus Guardwire Plus for thrombectomy in patients with inferior myocardial infarction: a t

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:userlyc
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background Different feasible and safe thrombectomy and distal protection devices have been used in clinical practice.The efficiency and safety of adjunct thrombectomy using Diver CE device (Invatec, Italy) versus Guardwire Plus device(Medtronic, USA) before percutaneous coronary intervention (PCI) were compared in patients with acute inferior ST-segment-elevation myocardial infarction (STEMI) for less than 12 hours, thrombolysis in myocardial infarction (TIMI)flow grade 0 to 1, and total occlusion of the proximal right coronary artery (≥3 mm in diameter) in a prospective randomized single-center study.Methods The primary end point was the magnitude of ST-segment resolution (STR) (>70%) measured immediately, 90minutes and 6 hours after PCI, myocardial blush grade and slow flow or no-reflow. Secondary end points were left ventricular end-diastolic volume (LVEDV), left ventricle ejection fraction (LVEF) and major adverse cardiac events (MACEs) including death, myocardial infarction, target vessel revascularization and stroke at 30 days.Results A total of 122 patients were equally divided into Diver CE group and Guardwire Plus group, which were comparable by age ((60± 14) years vs (60± 13) years), male (82% vs 84%), diabetes (31% vs 28%), previous coronary artery disease (25% vs 23%), onset-to-angiogram ((350± 185) min vs (345± 180) min), and use of glycoprotein Ⅱb/Ⅲa inhibitor (11% vs 13%). The magnitude of ST-segment resolution was similar in the two groups as ST-segment resolution >70% (57% vs 59%; P>0.05). Similar slow flow/no-reflow rates were observed in the Diver CE group (8%) and the Guardwire Plus group (7%). TIMI flow grade 3 was obtained in 95% vs 97% patients, respectively (P>0.05). Myocardial blush grade 3 was similar (70% vs 72%; P>0.05). Thirty-day clinical outcome was comparable (LVEF, 0.54±0.12 vs 0.53±0.11; death, 3% vs 3%; myocardial infarction, 2% vs 0%; and target vessel revascularization, 2% vs 2%; P>0.05,respectively).Conclusions Removal of thrombus burden with the Diver CE catheter before stenting leads to similar improvement of myocardial reperfusion in patients with inferior STEMI and total occlusion of the proximal right coronary artery (≥3 mm in diameter) compared with the Guardwire Plus device, as illustrated by a reduced risk of distal embolization and improved ST-segment resolution.
其他文献
A donor-bridge-donor compound for blue light-emitting with triphenylamine as donor and pentiptycene derivative units as bridge was synthesized via Sonogashira r
AIM:To evaluate the efficacy and mechanism of action of NCB-02,a standardized Curcumin preparation,against 2,4-dinitrochlorobenzene(DNCB)-induced ulcerative col
Background The safety and efficacy of drug-eluting stents (DES) implantation in unprotected left main (LM)bifurcation lesions has yet to be determined. The aim
为探究吕家坨井田地质构造格局,根据钻孔勘探资料,采用分形理论和趋势面分析方法,研究了井田7
In this paper, differential pulse voltammetry (DPV) was applied to study the effects of aluminum Al(Ⅲ) on the lactate dehydrogenase (LDH) activity. Michaelis-M
Genetic factors play a significant role in determining inflammatory bowel disease (IBD) susceptibility. Epidemiologic data support genetic contribution to the p
Fasciola hepatica, a leaf shaped trematode that is common in cattle, sheep and goats, is acquired by eating raw water plants like watercress or drinking water i
AIM: To investigate the incidence of KIT immunoho- stochemical staining in (GI) stromal tumors (GISTs), and to analyze the clinical manifestations of the tumors
Plaque rupture with subsequent thrombus formation is the common pathophysiological substrate of acute coronary syndrome (ACS).1 Moreno et al2 reported that neov