论文部分内容阅读
[摘要] 采用水解酸化-UASB-SBR工艺处理金黄色素生产废水,污水系统运行初期进水COD:2500~7800 mg/L。后期由于控制污水排放量,原水COD达到6000~17000mg/L,虽然水量减少了,但是原水浓度偏高,对生化系统的正常运行造成了压力,经过近半年的调整运行,污水处理系统逐步正常稳定化,能保证达标处理污水。
[关键词] 制药废水;UASB;SBR
Abstract: Hydrolytic Acidification-UASB-SBR process was used to treat wastewater produced in the process of producing aluminon . The COD in the influent was 2500~7800 mg/L. Late due to control sewage discharge, COD reaches 6000~ 17000mg / L, while the decrease of water, but the water concentration is too high, the biochemical system normal operation caused by the pressure, after nearly half a year of operation, sewage treatment system gradually normal stabilization, can guarantee the compliance of sewage treatment
Key words: pharmaceutical wastewater;up-flow anaerobic sludge blanket;sequencing batch reactor
中图分类号:X703文献标识码:A 文章编号:
本文主要介绍水解酸化-UASB-SBR工艺在处理金黄色素生产废水中的应用以及后期污水水量及COD变化调整运行参数的运行情况跟踪分析。厌氧-好氧组合处理工艺已在制药废水的处理中得到广泛应用[1]。
1 工程概况
1.1水量及进出水水质
内蒙古某制药厂主要生产金黄色素,废水水量为650m3/d。废水中的主要污染物为糖类物质、甲醇、乙醇、氨氮和微生物丝菌体蛋白质等。进水水质及处理要求见表1:
表1 进水水质及排放标准
处理系统运行前期,日处理量为650吨,后期为响应国家节能减排的号召,工厂生产车间将设备、地面清洗水进行了严格控制,污水量减少至220-350吨/天,废水COD平均从5000mg/L提升至17000mg/L,这给生化系统运行带来较大的困难【2】。对运行参数调整四个月后,药厂生产排水基本稳定,进水水质也逐步趋于稳定。
2 调整运行的效果
2.1 UASB处理效果及分析
UASB污泥量约为11kgVSS/m3。原水温度在35~40℃之间,能保证UASB的水温在正常范围内。
2.1.1 负荷调整方式及过程
运行过程中为避免UASB容积负荷的剧烈变化,UASB的进水量主要依据进水COD容积负荷来控制。启动初期,UASB采用较小的容积负荷。启动过程中,如果连续数天UASB的COD去除率大于80%且出水VFA小于3mmol/L,说明反应器运行情况良好,应适度提高容积负荷。UASB容积负荷的提高以及进出水COD的变化情况如图2:
图2 UASB容积负荷及进出水COD
图2所示,把UASB的启动过程大致分为三个阶段:① 调整初始阶段(1~49d)。在这一阶段中,完成了污泥对进水水质的驯化,并把容积负荷提高到2.1kgCOD/(m3•d)。本阶段中进水COD在8000~10000mg/L范围内变化,出水COD变化幅度较小,能够稳定在950mg/L以下,COD去除率大于86%。② 负荷提高阶段(50~134d)。UASB容积负荷逐步提高,直到满负荷运行。65~100d期间,UASB进水硫酸盐的增高,降低了厌氧对COD的去除效率,使得出水COD大于1000mg/L,期间容积负荷没有增加。③ 高负荷运行阶段(135~155d)。UASB进水量约为260m3/d,进水COD稳定在15000mg/L左右,容积负荷达到4.9kgCOD/(m3•d),出水COD小于1000mg/L,COD去除率稳定在85%以上。
2.2 SBR的運行
由于厌氧系统调整负荷期间,洗出部分絮状污泥,造成好氧系统暂时缺氧,SBR经闷爆,三天后活性污泥泥色由黑变成土黄色,出现原生动物,多数为游泳型纤毛虫。接着把污泥进水负荷控制在0.25kgCOD/(kgMLSS•d),七天后出水达标。镜检发现污泥中的原生动物以钟虫等固着型纤毛虫为主,这表明活性污泥运转情况良好。为保证出水水质,把污泥浓度控制在4000mg/L以下,把DO控制在2-4mg/L。
运行过程中,污泥沉降性能良好,SVI稳定在50~90ml/g。SBR满负荷运行后,运行周期确定为8.5h,其中:进水2.5h,曝气4.5h,静沉30min,排水30min,闲置30min。出水COD为160~290mg/L,氨氮小于19mg/L,水质各项指标达到处理要求。
3 系统处理效果
系统调整运行参数满负荷运行后,又进行了4个月的观察。结果表明该工艺处理效果稳定,出水水质达标。表4列出了不同时间各工段的出水水质:
表4不同时间各工艺段的出水水质情况
4 结论
(1) 采用水解酸化—UASB—SBR工艺能有效处理金黄色素生产废水。结果表明,该工艺具有污染物去除效率高、运行经济稳定等特点,当容积符合控制稳定的情况,可以调整污水浓度及污水量,从而达到节能减排、降低运行费用的效果。
(2) 原水浓度增大后,要严格控制其波动范围,防止非人为因素造成的厌氧系统容积负荷波动,对生化系统造成冲击。
[参考文献]
[1] 王其侠. 复合水解酸化/完全混合生物工艺处理制药废水试验研究[硕士论文]. 哈尔滨工业大学,2002.
[2] 王绍文,罗志腾,钱雷. 高浓度有机废水处理技术与工程应用[M]. 北京:冶金工业出版社,2003:139—141.
注:文章内所有公式及图表请以PDF形式查看。
[关键词] 制药废水;UASB;SBR
Abstract: Hydrolytic Acidification-UASB-SBR process was used to treat wastewater produced in the process of producing aluminon . The COD in the influent was 2500~7800 mg/L. Late due to control sewage discharge, COD reaches 6000~ 17000mg / L, while the decrease of water, but the water concentration is too high, the biochemical system normal operation caused by the pressure, after nearly half a year of operation, sewage treatment system gradually normal stabilization, can guarantee the compliance of sewage treatment
Key words: pharmaceutical wastewater;up-flow anaerobic sludge blanket;sequencing batch reactor
中图分类号:X703文献标识码:A 文章编号:
本文主要介绍水解酸化-UASB-SBR工艺在处理金黄色素生产废水中的应用以及后期污水水量及COD变化调整运行参数的运行情况跟踪分析。厌氧-好氧组合处理工艺已在制药废水的处理中得到广泛应用[1]。
1 工程概况
1.1水量及进出水水质
内蒙古某制药厂主要生产金黄色素,废水水量为650m3/d。废水中的主要污染物为糖类物质、甲醇、乙醇、氨氮和微生物丝菌体蛋白质等。进水水质及处理要求见表1:
表1 进水水质及排放标准
处理系统运行前期,日处理量为650吨,后期为响应国家节能减排的号召,工厂生产车间将设备、地面清洗水进行了严格控制,污水量减少至220-350吨/天,废水COD平均从5000mg/L提升至17000mg/L,这给生化系统运行带来较大的困难【2】。对运行参数调整四个月后,药厂生产排水基本稳定,进水水质也逐步趋于稳定。
2 调整运行的效果
2.1 UASB处理效果及分析
UASB污泥量约为11kgVSS/m3。原水温度在35~40℃之间,能保证UASB的水温在正常范围内。
2.1.1 负荷调整方式及过程
运行过程中为避免UASB容积负荷的剧烈变化,UASB的进水量主要依据进水COD容积负荷来控制。启动初期,UASB采用较小的容积负荷。启动过程中,如果连续数天UASB的COD去除率大于80%且出水VFA小于3mmol/L,说明反应器运行情况良好,应适度提高容积负荷。UASB容积负荷的提高以及进出水COD的变化情况如图2:
图2 UASB容积负荷及进出水COD
图2所示,把UASB的启动过程大致分为三个阶段:① 调整初始阶段(1~49d)。在这一阶段中,完成了污泥对进水水质的驯化,并把容积负荷提高到2.1kgCOD/(m3•d)。本阶段中进水COD在8000~10000mg/L范围内变化,出水COD变化幅度较小,能够稳定在950mg/L以下,COD去除率大于86%。② 负荷提高阶段(50~134d)。UASB容积负荷逐步提高,直到满负荷运行。65~100d期间,UASB进水硫酸盐的增高,降低了厌氧对COD的去除效率,使得出水COD大于1000mg/L,期间容积负荷没有增加。③ 高负荷运行阶段(135~155d)。UASB进水量约为260m3/d,进水COD稳定在15000mg/L左右,容积负荷达到4.9kgCOD/(m3•d),出水COD小于1000mg/L,COD去除率稳定在85%以上。
2.2 SBR的運行
由于厌氧系统调整负荷期间,洗出部分絮状污泥,造成好氧系统暂时缺氧,SBR经闷爆,三天后活性污泥泥色由黑变成土黄色,出现原生动物,多数为游泳型纤毛虫。接着把污泥进水负荷控制在0.25kgCOD/(kgMLSS•d),七天后出水达标。镜检发现污泥中的原生动物以钟虫等固着型纤毛虫为主,这表明活性污泥运转情况良好。为保证出水水质,把污泥浓度控制在4000mg/L以下,把DO控制在2-4mg/L。
运行过程中,污泥沉降性能良好,SVI稳定在50~90ml/g。SBR满负荷运行后,运行周期确定为8.5h,其中:进水2.5h,曝气4.5h,静沉30min,排水30min,闲置30min。出水COD为160~290mg/L,氨氮小于19mg/L,水质各项指标达到处理要求。
3 系统处理效果
系统调整运行参数满负荷运行后,又进行了4个月的观察。结果表明该工艺处理效果稳定,出水水质达标。表4列出了不同时间各工段的出水水质:
表4不同时间各工艺段的出水水质情况
4 结论
(1) 采用水解酸化—UASB—SBR工艺能有效处理金黄色素生产废水。结果表明,该工艺具有污染物去除效率高、运行经济稳定等特点,当容积符合控制稳定的情况,可以调整污水浓度及污水量,从而达到节能减排、降低运行费用的效果。
(2) 原水浓度增大后,要严格控制其波动范围,防止非人为因素造成的厌氧系统容积负荷波动,对生化系统造成冲击。
[参考文献]
[1] 王其侠. 复合水解酸化/完全混合生物工艺处理制药废水试验研究[硕士论文]. 哈尔滨工业大学,2002.
[2] 王绍文,罗志腾,钱雷. 高浓度有机废水处理技术与工程应用[M]. 北京:冶金工业出版社,2003:139—141.