论文部分内容阅读
国家质检总局2002年颁布的《起重机械监督检验规程》性能试验中的静载试验和额定载荷试验中的检验方法是用水准仪或经纬仪等专用仪器测其前后差值。这类检验检测方法得到的数据合理、精确,受现场影响的因素少。但使用的仪器设备较笨重,且调整时间过长,对于检验任务重,设备数量多的地域,尤其是要在好几个单位检验,中间需要转场的,相当一部分检验时间被浪费,无形中影响了检验的质量,这种方法也就不太适用,在此推荐一种简易检验方法,以供大家参考。随着现代工业的快速发展,工业厂房的规模也越来越大,同时,现代化工业的要求越来越高,对车间内的地坪面层也提出了更高的要求,这就对厂房地面
AQSIQ promulgated in 2002, “lifting machinery supervision and inspection procedures” performance test static load test and rated load test in the test method is to use the level or theodolite and other special instruments to measure the difference before and after. The data obtained from such inspection and detection methods are reasonable, accurate and less affected by on-site factors. However, the equipment used is bulky and the adjusting time is too long. For the areas where the inspection tasks are heavy and the equipment quantity is large, in particular, the inspection needs to be performed in several units, the transitional process is required in the middle, and a considerable amount of inspection time is wasted, The quality of the test, this method is not suitable, recommended a simple test method for your reference. With the rapid development of modern industry, the scale of industrial plants is also growing. At the same time, the requirements of the modern industry are getting higher and higher, and higher demands are also placed on the floor surface in the workshop.