The indoor parameters are generally non-uniform distributed. Consequently, it is important to study the space cooling/heating load oriented to local requirements. Though the influence of indoor set point, heat sources, and ambient temperature of convective thermal boundary on cooling/heating load has been investigated in the uniform environment in previous research, the influence of these factors, particularly the convective heat gain/loss through a building envelope, on cooling/heating load of non-uniform environment has not yet been investigated. Therefore, based on the explicit expression of indoor temperature under the convective boundary condition, the expression of space cooling/heating load with convective heat transfer from the building envelope is derived and compared through case studies. The results can be summarized as follows. (1) The convective heat transferred through the building envelope is significantly related to the airflow patterns: the heating load in the case with ceiling supply air, where the supply air has a smaller contribution to the local zone, is 24% higher than that in the case with bottom supply air. (2) The degree of influence from each thermal boundary to the local zone of space cooling cases is close to that of a uniform environment, while the influence of each factor, particularly that of supply air, is non-uniformly distributed in space heating. (3) It is possible to enhance the influence of supply air and heat source with a reasonable airflow pattern to reduce the space heating load. In general, the findings of this study can be used to guide the energy savings of rooms with non-uniform environments for space cooling/heating.
其他文献
Air velocity and temperature distributions inside operating rooms (ORs) play a crucial role to reduce the risk of infections and to ensure adequate comfort cond
The aim of the study is to investigate the influence of geometry on the thermal capacity and stratifications of a water pit heat storage for solar district heat
In this study, the aerodynamic characteristics of tall buildings with corner modifications (e.g., local wind force coefficients, mean pressure distributions, no
Large metro transfer stations have been widely constructed in China, among which the double-island station faces the serious fire safety issues owing to its lar
In Latin America, default assumptions and borrowed templates and methodologies are often used in energy modeling, resulting in models that might not represent t
While the primary role of window attachments is often to moderate glare and solar heat gains, they are also able to provide additional daylight to interior spac
To improve the prediction accuracy of heating demand, an appropriate base temperature should be estimated before using the heating degree-days (HDD) approach. T
A major roadblock in achieving substantial building energy reduction is the low performance of old buildings that account for a significant portion of the build
Ceiling fans are used all over the world as a mean of enhancing indoor thermal comfort. A number of grading programs have been initiated for assessing energy pe
Architects welcome double skin facade (DSF) due to its aesthetic quality. The first DSF structure was intended to prevent cold weather and strong winds. Nowaday