Reproducibility and accuracy of quantitative assessment of articular cartilage volume measurements w

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:lhmfly
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background Quantitative magnetic resonance imaging (qMRI) of articular cartilage represents a powerful tool in osteoarthritis research, but has so far been confined to a field strength of 1.5 T. The aim of the study was to determine the reproducibility and accuracy of qMRI assessments of the knee cartilage volume by comparing quantitative swine cartilage volumes of the sagittal (sag) multi echo data imagine combination water-excitation (MEDICwe) sequence and the fast low-angle shoot water-excitation (FLASHwe) sequence at 3.0-T MRI to directly measured volumes (DMV) of the surgically removed articular cartilage.Methods Test-retest MRI was acquired in 20 swine knees. Two sag FLASHwe sequences and two sag MEDICwe sequences (spatial resolution 0.4 mm × 0.4 mm × 1.0 mm of 3-dimension (3D) were acquired at 3-T MRI in a knee.Articular cartilage volume was calculated from 3D reformations of the MRI by using a manual program. Calculated volumes were compared with DMV of the surgically removed articular cartilage. Knee joint cartilage plates were quantified paired in order.Results In the knee joint of swine, reproducibility errors (paired analysis) for cartilage volume were 2.5% to 3.2% with sag FLASHwe, and 1.6% to 3.0% with sag MEDICwe. Correlation coefficients between results obtained with qMRI and DMV ranged from 0.90 to 0.98 for cartilage volume. Systematic pairwise difference between results obtained with qMRI and DMV ranged from -1.1% to 2.8%. Random pairwise differences between results obtained with qMRI and DMV ranged from (2.9 ±2.4)% to (6.8±4.5)%.Conclusions FLASHwe and MEDICwe sequences permit highly accurate and reproducible analysis of cartilage volume in the knee joints of swine at 3-T MRI. Cartilage volume reproducibility for the MEDICwe data is slightly higher than the FLASHwe data.
其他文献
影响大坝安全的因素多、范围广。大坝安全监测必须具有鲜明的针对性,坚持设计及大坝安全定检相结合,尤其要加强对溃坝的科学研究,努力实现大坝安全监测网络化、智能化、效益化。
油井其它增产技术是利用油层渗透能力提高而达到增产的目的,CO2吞吐技术却是利用CO2注入原油后,使原油粘度降低和原油体积膨胀机理,使油层里渗透能力和驱油动力同时提高而达
目的 探讨前路经皮内窥镜下颈椎间盘髓核摘除术(percutanous endoscopic cervical discectomy,PECD)的安全性、可行性及临床疗效. 方法 选择用PECD治疗的28例患者.术前及术后3d、1,3,6,12及18个月分别行视觉模拟评分(visual analogue scale,VAS)及MacNab评分.术后1,3及12个月行MRI检查.所有评分数据收集后使用
纳洛酮(Naloxone,NX)又名烯丙羟吗啡酮,为羟-2氢吗啡酮衍生物,是阿片受体特异拮抗剂,血中半衰期短,静脉给药起效快,吸收迅速,易透过血脑屏障,代谢较快,作用持续45~90min,故需
在于2011年开展的一项研究因论文作者允许肿瘤在小鼠体内长得过大而受到批评后,《自然》杂志正在修改其关于发表动物试验的政策.当时的论文报告称,一种从胡椒中分离出来的化
期刊
近日在荷兰,Groningen大学的研究人员已经开发出一种可3D打印的抗菌塑料,这种材料主要用于光固化成形工艺,当把它与涂唾液样本放在一起时,它可以有效杀灭超过99%的变形链球菌,
期刊
Coronary vasospasm is a rare diagnosis resulting in sudden arrhythmic cardiac arrest. We report a case of a healthy,non-smoking elderly woman resuscitated from
环氧化酶-2(COX-2)是环氧化酶的诱导型,是催化花生四稀酸合成前列素的限速酶。COX-2在肿瘤细胞生长、细胞凋亡和肿瘤血管生成方面发挥重要作用。COX-2与肿瘤关系密切,现对其
期刊