成都污水处理厂 2期工程中的污泥消化池内径为 2 7m ,高为 2 0m ,共 4座 ,在该构筑物的设计中 ,采用了环向无粘结预应力结构设计方案 ,以满足大直径、高水位消化池柱壳环向预应力值较高的要求 ,并取得了较好的经济技术指标。本文简要介绍了该消化池预应力部分的设计和施工
In the second phase of Chengdu Sewage Treatment Plant, the sludge digester has an inner diameter of 27 m and a height of 20 m, a total of four. In the design of the structure, a ring-bound unbonded prestressed structural design was adopted to meet the requirement of large Diameter and high water level digester cylinder shell ring to the higher pre-stress requirements, and achieved good economic and technical indicators. This article briefly introduces the design and construction of pre-stressing section of this digester