利用夹点技术,对某炼厂550万吨/年常减压装置的换热网络进行了优化研究。通过EXCLE电子表格法求解问题表,计算得到△T_(min),使换热网络获得最小冷热公用工程。同时将解题表法所求夹点与Aspen Energy Analysis软件所求夹点进行对比。比较结果表明解题表法所求夹点准确可靠。通过优化,原油换后终温从299.5℃提高到308℃,每年能节省燃料约3436.82吨。
The use of pinch point technology, a refinery 5.5 million tons / year atmospheric and vacuum unit heat exchanger network optimization. By EXCLE spreadsheet method to solve the problem table, calculated △ T_ (min), so that the heat exchange network access to the smallest hot and cold public works. At the same time, the solution to the problem table pinch point and Aspen Energy Analysis software for the pinch point comparison. Comparison results show that the solution to the problem of pinching points accurate and reliable. Through optimization, the final temperature of crude oil after the change from 299.5 ℃ to 308 ℃, annual savings of about 3436.82 tons of fuel.