论文部分内容阅读
随着建筑节能工作的开展,我国对其施工质量的验收标准进行了规范,指出在外墙外保温系统中,保温板材与建筑基层之间的粘结必须牢靠,粘结方式和粘结强度必须符合设计要求,保温板材与基层之间的粘结强度要进行现场拉拔试验。本文简要分析了现阶段我国建筑工程中保温板材与基层粘结强度检验的现状,介绍了不同板材对应的检验方法以及其各自的不足,并针对问题对现场拉拔试验提出了相应的建议,旨在为相关技术研究人员提供参考。
With the development of building energy conservation, China has standardized its acceptance standards for construction quality, pointing out that in the exterior insulation system, the bonding between the insulation board and the building base must be solid, the bonding method and bonding strength must be consistent Design requirements, insulation board and grass-roots bonding strength between the site for pull-out test. This paper briefly analyzes the current status of the test of bond strength between insulation board and grassroots in the current construction of our country, introduces the corresponding test methods of different boards and their respective deficiencies, and puts forward the corresponding suggestions for the site pull-out test. In the relevant technical researchers for reference.